The AstraTouch Desktop Spirometer provides easy navigation when performing comprehensive spirometry testing. Its multi-functional capabilities enable diagnostic decisions from the screen data, from its resident printer or off-line report writers. PC links via USB or optional Bluetooth simplifies the process of data storage, EMR transfers and real-time direct testing.
Designed to be accurate and easy to use, the simplicity of operation and wealth of configurability options expand the scope of spirometry testing like never before.
VIDEO
Features and Benefits
Quick and easy data entry, wireless navigation, accuracy and precision without calibration allow quick test results
Expanded testing capabilities with quality test assurance meet all clinic needs
Measures over 40 parameters of FVC, VC, MVV with choice of 16 predicted sets
Real-time PC testing, archiving or EMR maximizes communication and telemedicine capabilities
Better patient cooperation and assures patient effort
Social Security Disability-testing capable
Meets NIOSH standards
Audible end-of test-alert
Optional features include pulse oximetry, MIP/MEP, weather station, calibration syringe, carrying case and Ethernet connectivity
Materials Included
Astratouch Desktop Spirometer w/ full color touchscreen display
AccuFlo digital turbine
AstraPro software
On-board thermal printer
(2) Printer Paper Rolls
(50) Mouthpieces
User Manual
Technical Specifications
Forced Parameters Measured
Forced Vital Capacity:
FVC, FEV1, FEV1/FVC, PEF, FEF50%FEV6, FEV1/FEC, PEF, FEF50%, FEF25-75%, FEV6, FEV1/FEV0.5, PEFT, Vext, FIVC, FIF50%, FEF50/FIF50, QC Grades, FEV .5, FEV3, FEV.5/FVC, FEV3/FVC,FEV1/VC, FEV1/FEV6, FEV1/PEF, FEV1/FIV1, PEF/PIF, FEF25%, FEF75%, FEF75-85%, FET25-75%, FET100, FIV1, FIV1/FIVC, PIF, MTT, MVVInd, Lung age
MVV: MVV, Br./min
Bronchoconstriction: FVC, FEV1, PEF, FEF25-75%, PDx
Relaxed Parameters Measured
VC: VC, TV, ERV, IRV, IC, Ti, Te, Tt, Ti/Tt
Maneuvers per patient: 8 total; best test and last test highlighted
Interpretation: Selectable -- Kory, Miller, ATS, NLHEP (Ferguson)
Predicted sets: Selectable -- 16 Total
Ethnic correction: Selectable -- % Actual, Caucasian, Hispanic, AfroAmerican
Language: Selectable -- English, Spanish or French
Measurement Scale (BTPS)
Flow range: 0-16 L/sec
Volume: 0-10 L
Measurement method: Infrared Interruption via Digital Turbine
Dynamic flow resistance: <1.5 cm H20/L/sec @14 L/sec
Measurement Precision (BTPS)
At highest volume: +/- 3% or 50 mL
At highest flow: +/- 5% or 150 mL
Time related precision: .5%
Volume resolution: <6 mL
Sampling frequency: 50 Hz
Hardware Specifications
Storage capacity: 3000+ study database
Display: 5.7” High resolution color VGA touchscreen
Communication: USB to printer and PC, RS232, HL-7*
Dimensions: 7.7” x 10.6”x 3.9”
Weight: 3.7 lbs.
Power supply: 110 to 240V, 50 to 60 Hz or NiMH battery pack
Storage Temperature: -4oF to 158oF
Printer: 110 mm thermal graphic printer
Documentation