Features and Benefits
  • 12.1 LCD display, high resolution,
  • Large number display for long distance vision
  • Digital SPO2 technology offers anti-motion and anti-low perfusion funtions
  • Up to 66 beds network capacity to connect with HIS
  • 168 hours tabular and graphic trends & data storage
  • Drug dose calculation
  • OXYCRG software
  • Bed to bed view
Technical Specifications

General
  • Safety: IEC60601 (GB9706)
  • Dimension: 318mm (W) x 264mm (H) x 152mm(D)
  • Power Supply : 100~240V; AC: 50~ 60 Hz
  • Alarm Indication: Visual and audible alarm
  • 1800 groups of alarm events review
  • Application: Adult, Pediatric and neonate
ECG
  • Leads: I, II, III, aVR, aVL, aVF, V
  • Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
  • Input impedance: =5MO (d.c.~60Hz)
  • Common Mode Rejection Ratio: =85dB(diagnostic mode)
  • =105dB(monitoring & surgica mode)
  • Bandwith: 0.5-40Hz (monitoring mode)
  • 0.05-120Hz(diagnostic mode)
  • 1-25Hz (surgical mode)
  • Protection: Segregation breakdown voltage 4000VAC, 50/60Hz
  • Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
  • Indication of Detachment of electrodes: Available
  • Playback of Cardiogram: Available
  • Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
  • Heart Rate Range:10-300BPM
  • Accuracy: 1BPM
  • ECG waveform playback: 30 minutes
NIBP
  • Method: Automatic oscillometric
  • Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
  • Measurement : Systolic pressure/diastolic pressure/mean pressure
  • Range: Adult: 10-270mmHg
  • Pediatric: 10-235mmHg
  • Neonate: 10-135mmHg
  • Unit: mmHg / Kpa selectable
  • Auto Measurement: 1,2,3,4,5,10,15,20,30,45,60,90 minutes, 2,4,8, hours
  • 1000 groups of NIBP measuring data review
RESP
  • Method: Impedance Measurement
  • Measuring Range: 0-120bpm
  • Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
  • Apnea alarm: Available
BLT Digital SPO2 (Pulse Oximetry)
  • Range: 0-100%
  • Accuracy: 2% (70%~100%);
  • 3%(35%~ 69%)
  • Unspecified (0~34%)
  • Range & Accuracy of Pulse Rate : 20~250BPM 1BPM
TEMP
  • Channel : 2 channels
  • Range : 0~50
  • Unit : Celsius, Fahrenheit
  • Resolution : 0.1
  • Accuracy : 0.1 (25~50)
  • Alarm Range : 0~50
IBP
  • Channel : 2 channels
  • Range : -50~300 mmHg
  • Resolution : 1 mmHg
  • Accuracy : 2 mmHg (2%) without probe, 4 mmHg (2%) with probe
  • Unit : mmHg , Kpa
  • Converter sensitivity: 5 uV/V/mmHg
  • Names of pressures: ART/PA/CVP/LAP/RAP/ICP
EtCO2 (side stream)
  • Method: Infrared spectrum
  • Range: 0.0-13.1%
  • Resolution : 1 mmHg (0.1%)
  • Accuracy : <5% EtCO2, 0.3%
  • >5% EtCO2, <10% (of Readings)
EtCO2 (main stream)
  • Method: Infrared spectrum
  • Range: 0.0-10% (0-76mmHg)
  • Resolution : 1 mmHg (0.1%)
  • Accuracy : 5% (4.0 mmHg) or <10% (of Readings)
IRMA multi-gas (main stream)
  • Measure method: Infrared spectrum
  • Fi and ET values: CO2,N2O,O2,agent(HAL, ISO, ENF, SEV, DES)
  • Resolution: 1mmHg
  • Unit: %, mmHg
  • Calibration: Room air calibration performed automatically when changing airway adapter (<5 sec)
  • Warm-up time: 5s
  • Measuring and alarm range of multi-gas:
  • CO2: 0-10 % ,0.3% or 6% of reading, whichever is greater
  • N2O: 0-100 %, 2% or 8% of reading, whichever is greater
  • O2: 0-100 %, 3 %
  • HAL, ISO, ENF: 0-5%, 0.15% or 8% of reading, whichever is greater
  • SEV: 0-8%, 0.15% or 8% of reading, whichever is greater
  • DES: 0-18%, 0.15% or 8% of reading, whichever is greater
  • Respiration rate Measuring alarm range and accuracy: 3~100 bpm, 1 bpm
  • Alarm indication: Sound and light indication
Environment Conditions
  • Temperature: Operation 0-40
  • Storage / Transportation : -20-50
  • Humidity: Operation: =85% noncondensing
  • Storage / Transportation : =93% noncondensing
  • Atmospheric Pressure: Operation: 860~1060hPa
  • Storage / Transportation : 500~1060hPa
Technical Specifications
  • 3-year warranty

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Vital Sign Monitors
 
Welch Allyn Authorized Distributor Volusion Secure Site ABOUT TRUST ONLINE Medical Device Depot is a ShopWiki Approved Store Become.com DOTmed Certified: Medical Device Depot PayPal Verified
BBB Accredited Business Physio Control Payment Options Compare prices at WillyFogg.com