This product has been discontinued. For comparable products, click here for the following: The BM7Vet boasts optional dual IBP modules, EtCO2 and anesthetic gas module, on top of standard ECG, Respiration, NIBP Dual Temp and SpO2. It's 12.1" wide color monitor displays all the vital signs that you want in different colors. Built-in printer offers documentation of all measured values as well as up to 3 waveformes of information. Alarms and settings are easily adjustable and are retained after turning off the power.
Features and Benefits
- 12.1" Touch Screen High Resolution Widescreen
- 58mm Built-In Printer
- 168 Hour Memory Capacity, Rechargable Battery
- 6 Traces, ST Analysis, PVC Count, Full Arrhythmia Package, USB Flash Drive Interface, EtCO2/Anesthetic Gases Module Interface
- 29 x 19 Sec Alarms Saved (Save, Review and Print)
- Multiple Display Modes and Freeze Function
- Can Connect External Monitor
- Optional Dual Gas Sensor Module Available
- Monitor both EtCO2 and Anesthetic Gases with a Dual Gas Sensor Module. Gases monitored include: isoflurane, enflurane, halothane, desflurane and sevoflurane. The Dual Gas Sensor Module includes 1 Water Trap, 1 Sample Line, 1 Airway adapter, 1 Mounting Kit.
Note: In order to do Invasive Blood Pressure (IBP), you will need to purchase the required accessories below:
- C-Fusor 1000ml Pressure Infusor - (MX4810)
- TranStar® 60" Single Line Monitoring Kit (MX9504T)
- TranStar® Reusable Single Channel Cable (MX95114)
Sample Screenshots
Materials Included
- 3 Lead Vet ECG Cable
- NIBP extension tube (3m)
- NIBP vet cuff neonate disposable #1-#5
- NIBP vet cuff infant reusable
- SpO2 extension cable (2m)
- Esophageal probe
- Transflectance SpO2 Probe
- Temperature Probe (rectal/esophageal)
- Reusable multisite SpO2 probe
- B-Link auotomated record keeping software
- DC adapter (18 VDC, 2.5A)
Technical Specifications
General - Display, Resolution: 12.1" Touch Screen
- Dimensions: 12.7" x 9.8" x 8.9"
- Trace
- 6 Waveforms: 2 ECG, SpO2, RR or EtCO2, 2 IBP
- Sweep Speed: 6.25, 12.5, 25, 50 mm/sec
- Indicators
- Categorized alarms (3 priority levels)
- Heart beat tone
- Visual alarm lamp handle
- Spo2 pulse pitch tone
- Battery status, external power LED
- Touch screen, rotary knob
- Interfaces
- DC input connector: 18 VDC, 2.5A
- Defibrillator Sync. Output
- Signal Level: 0 to 5 V pulse
- Pulse Width: 100 ± 10ms
- LAN digital output for transferring data
- Nurse call system connection
- - 0.3 A at 125 VAC
- - 1 A at 24 VAC
- DC output: 5VDC, 1A Max
- Battery
- Rechargeable Li-ion battery
- 2 hours of continuous operation
- Thermal Printer
- Speed: 25, 50 mm/sec
- Paper width: 58 mm
- Data Storage: Monitoring Mode: 168-hour trends, 20 cases of 10-sec alarm waveform
- Language: English, French, Spanish, Italian, German, Chinese, Russian, Czech, Polish, Turkish, Romanian, Portuguese, Bulgarian, Korean, Hungarian
Performance
- ECG
- Lead Type: 3-lead, 5-lead
- Lead Selection
- 3-lead: I, II, III
- 5-lead: I, II, III, aVR, aVL, aVF, V
- Heart Rate Range
- Horse, Dog: 30 - 300 bpm
- Puppy, Cat: 30 - 350 bpm
- Heart Rate Accuracy: +/-1 bpm or +/- 1%, whichever is greater
- Sweep Speed: 6.25, 12.5, 25, 50 mm/sec
- Filter
- Diagnosis: 0.05 - 150HZ
- Monitoring: 0.5 - 40Hz
- Moderate: 0.5 - 25Hz
- Maximum: 5 - 25 Hz
- S-T Segment Detection Range: -2.0 to 2.0 mV
- Arrhythmia Analysis: Asistole, VTACH, V-fib, bigeminy, accvent, couplet, irregular, pause, PVC, ront, trigeminy, VBRADY, short run
- Pacemaker Detection Mode: Indicator on waveform display, user selectable
- Protection: Against electrosurgical interference and defibrillation
- Respiration
- Method: Thoracic impedance
- Channel Selection: RA-LA or RA-LL
- Measurement Range: 5 - 120 breaths per minute
- Accuracy: +/- 1 breath per minute
- Apnea Alarm: Yes
- SpO2
- Saturation Range: 0 to 100 %
- Saturation Accuracy: 70 to 100 % +/- 2 digits, 0 to 69 % unspecified
- Pulse Rate Range: 30 to 254 bpm
- Pulse Rate Accuracy: +/- 2 bpm
- NIBP
- Method: Oscillometric
- Operation Mode: Manual / Automatic / Continuous
- Pressure Range: 0 - 300 mmHg (± 3 mmHg)
- Measurement Range: Systolic: 40 - 265 mmHg
- MAP: 27 - 222 mmHg
- Diastolic: 20 - 200 mmHg
- Pulse Rate Range: 25 - 300 BPM
- Temperature
- Channels: 2
- Measurement Range: 0 to 50°C (32°F to 122°F)
- Accuracy: +/-1°C
- Compatibility: YS1 Series 400 temperature probes
- IBP (Option)
- Channels: 2
- Measuring Range: -50 to 300 mmHg
- Accuracy
- Less than 100 mmHg: +/- 1 mmHg
- Equal or greater than 100 mmHg: +/- 1% of reading
- Pulse Rate Range: 0 to 300 bpm
- Zero Balancing
- Range: +/- 200 mmHg
- Accuracy: +/- 1 mmHg
- Drift: +/- 1 mmHg over 24 hours
- Transducer Sensitivity: 5_v/V/mmHg
- Mainstream CO2 (Option)
- Measurement Range: 0 to 150 mmHg, 0 to 19%
- Accuracy
- 0 - 40 mmHg +/- 2 mmHg
- 41 - 70 mmHg +/- 5% of reading
- 71 - 100 mmHg +/- 8% of reading
- 101 - 150 mmHg +/- 10% of reading
- Respiration Rate: 0 to 150 breaths per minute
- Respiration Accuracy: +/- 1 breath per minute
- Sidestream CO2 (Option)
- Measurement Range: 0 to 150 mmHg, 0 to 19%
- Accuracy
- 0 - 40 mmHg +/- 2 mmHg
- 41 - 70 mmHg +/- 5% of reading
- 71 - 100 mmHg +/- 8% of reading
- 101 - 150 mmHg +/- 10% of reading
- Respiration Rate: 2 to 150 breaths per minute
- Respiration Accuracy: +/- 1 breath per minute
- Dual Gas (Option)
- Method: Sidestream
- Gas: CO2, ISO, Sev, Enf, Hal, Des
- Range, Accuracy
- CO2: 0-10%, ± (0.2 vol% + 4% relative)
- Iso/Sev/Enf/Hal: 0-6%, ± (0.15% vol% + 4% relative)
- Des: 0-18%, ± (0.15% vol% + 4% relative)
- Respiration Rate: 0-150 BPM ±1 BPM
Warranty Information
Documentation Brochure
|
|
|