SmartSat™ Pulse Oximetry Analyzer is the most accurate
SpO2 Simulator available; it is affordable and reliable. SmartSat™ is one of the key SpO2 Analyzers and biomedical test equipment
devices used worldwide by leading hospital biomedical engineering
departments and clinical engineering departments to maintain pulse
oximeters, pulse oximeter probes and patient monitoring equipment.
Features and Benefits
- The only
SpO2 Simulator that provides unmatched accuracy with electrical
simulation and a pulse oximeter probe analyzer
- Includes built-in probe analyzer ports for directly testing Nellcor, BCI Nonin and Ohmeda probes with no cables necessary
- Other probe brands / models are tested using high quality probe analyzer
cables that "lock-in place" in the Ohmeda Probe Analyzer Port
- Includes advanced simulation features such as Arrhythmias, motion artifact and ambient light simulation
- Can be powered by its
internal NiMH battery or external AC power adapter
- Utilized by companies such as Nellcor, Masimo,
Criticare, Datascope, Philips, GE Medical, Welch Allyn, Alaris Medical
Systems and other leading pulse oximeter / patient monitoring
manufacturers
Sample Output
SpO2 Simulator -
Oxygen Saturation (SpO2) -
-
-
Range: | -
0-100 SpO2% | -
-
-
Resolution: | -
1 SpO2% | -
-
-
Accuracy: | -
-
±0.5 SpO2%, 70-100 SpO2%
- ±1 SpO2%, 50-69 SpO2%
-
| -
-
-
Pulse Rate -
-
-
Range: | -
20-300 BPM | -
-
-
Resolution: | -
1 BPM | -
-
-
Accuracy: | -
±1 BPM, 20-199 BPM
- ±2 BPM, 200-300 BPM
| -
-
-
R-Curves (Red/IR Ratio) -
R-Curves specify the relationship between the Red/IR ratio measured by pulse oximeters and the SpO2 value displayed . R-curves are obtained by each pulse oximeter manufacturer during clinical trials. -
Preset Manufacturer's R-Curves (14): BCI, Criticare, - CSI-Spot, Datascope, Datex, Hewlett-Packard (Philips), Masimo, Nellcor,
- Nellcor OxiMax, Nihon Kohden, Nonin, Novametrix, Ohmeda &
- Sensormedics
- Please contact the factory for the availability of other R-Curves.
-
Pulse Modulation Amplitude -
Simulates the effect of tissue perfusion -
-
-
Range: | -
0.10 - 20.0% | -
-
-
Resolution: | -
.05% | -
-
-
Ambient Light -
Simulates the ambient light level "seen" by the oximeter probe -
-
-
Range: | -
DC Level & AC | -
-
-
Level: | -
(5-255 DC) (0-255% AC)
-
| -
-
-
Resolution: | -
1% | -
-
-
Accuracy: | -
±1% | -
-
-
-
-
-
Flicker Frequency Presets (6): | -
60 Hz | -
-
-
| -
120 Hz | -
-
-
| -
121 Hz | -
-
-
| -
50 Hz | -
-
-
| -
100 Hz | -
-
-
| -
101 Hz | -
-
-
Motion Artifact -
-
-
Amplitude Range: | -
0-100 | -
-
-
Frequency: | -
4 Hz, Contact factory for availability of other frequencies. | -
-
-
Arrhythmias -
Simulates cardiac arrhythmias by altering the plethysmographic pulse amplitude and pulse rate. -
-
-
Arrhythmias (5): | -
Asystolic Pause | -
-
-
| -
PVC | -
-
-
| -
Atrial Fibrillation | -
-
-
| -
Tachycardia | -
-
-
| -
Bradycardia | -
-
-
Auto Sequences -
Preset Auto Sequences automate pulse oximeter testing. -
Standard Presets (18): -
- All autosequences are user configurable
-
- User configurations are saved, replacing factory samples
-
-
Factory Samples
- 100-58 - preset for 13 manufacturers
- 50-81 - preset for Nellcor and Ohmeda
- Trend Loop
- 4 Points
- Pulse Rate: 40-200
-
Remote Control -
The Smart Sat can be operated via remote control through its RS-232 port and duplicate all front panel operations. -
Probe Analyzer -
Probe Continuity Test -
Simultaneous Channels:
- 2 for Nellcor-style probes: LED & PhotoDiode circuits
- 3 for Ohmeda-style probes: Red LED, IR LED & PhotoDiode circuits
- Test Mode: Constant Current Stimulus, Voltage Output
- Constant Current Stimulus: 500 uA
- Intermittent "Glitch" Detection: Detects open circuits and short circuits, 1 msec or longer
- Probe Connection: Connectors for Nellcor & Ohmeda probes are built into SmartSat; other probes are connected via adapter cables
-
General -
Display -
Type: Backlit graphic LCD
- Resolution: 320 h x 240 v, 0.30mm dot pitch
- Controls: Contrast
-
Serial Interface -
Remote Control Mode
- Type: RS-232C, 9 pin "PC-AT" style
- Baud Rates: 1200 bps
-
Battery & AC Adapter -
Battery
- Type: Nickel Metal Hydride (NiMH)
- Voltage: 19.2V
- Capacity: 2.1A-Hr (About 4.5 Hours usage)
- Charge Time: 17 Hours (charges even if SmartSat in use)
- 24 VDC External AC Adapter : 120 VAC / 60 Hz, 38 watts
- or, 230 VAC / 50 Hz, or 100 VAC adapter as appropriate
-
Physical -
Case: Aluminum with non-skid feet & handle
- Dimensions: 8" Wide x 8" Deep x 5" High
- Weight: 4 pounds including battery
|
|
|
|
|
|
|