Home > Laboratory > Laboratory Balances > Radwag Laboratory Balances >

Radwag WLY 1/D2 Precision Balance
Radwag WLY 1/D2 Precision Balance


 
Additional Views:


List Price: $1,665.00
Our Price: $1,332.00
You save $333.00!




Product Code: WLY-1-D2

Details
 

Multifunctional WLY balance is intended for fast and precise determination of mass, performed using a modern PUE7 series indicator. Operation of the device is easy, with it weighing can be automated to the maximum. Apart from weighing, the WLY allows users to carry out parts counting, labeling and formula making processes. Its software enables integration with barcode scanners, receipt printers, label printers, RFID scanners and PC peripherals (including mouse, keyboard and external data storage devices) all connectable to built-in interfaces RS232, USB and Ethernet.


Features and Benefits
  • Data Exchange Through USB Storage Devices
    • Update Balance Software
    • Export Weighing Data
    • Export/Import Databases
    • Export/Import Balance Settings
    • Exchange Data Between Balances
  • Interfaces
    • Ethernet
    • 2×USB
    • 2×RS 232
    • 4 in / 4 out
    • WiFi 2,4GHz b,g,n
  • Infrared Proximity Sensors
    • Optional Functions:
      • Print function
      • Tare function
      • Sensor's sensitivity adjustment
Functions
  • Dosing: Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bar graph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
  • Labeling: Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labeling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
  • Plus/Minus Control: Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
  • Percent Weighing: Percent Weighing function is used for comparison of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly exceeded.
  • Totalizing: Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
  • Parts Counting: Function using mass measurement for determination of measured items quantity. Mass of a single item is required for this process. It may be either estimated through Weighments or taken from a database. For items counting the following algorithm is used: all items mass/single item mass = quantity. Function operation is supported by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with check weighing and dosing thus industry solutions feature audio signaling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platforms of different MAX capacities and different accuracies.
  • Peak Hold: Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
  • Formulation: Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
  • Statistics: Statistics function registers and analyses performed measurements. This supplies the user with the following information: Max and Min standard deviation, average value, variance, range et.
  • Check weighing: Check weighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and High [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signaled by means of pictograms located on a display for laboratory balances, for industrial scales stack light System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specified tolerance, e.g. 12860 g 961
  • IR Sensors: Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
  • Animal Weighing: Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
  • Differential Weighing: Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes. Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series. Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units. Density Determination: Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of under-pan weighing. Tested load of significant size may be measured this way.
  • ALIBI Memory: "ALIBI" memory enables saving and storing up to 100000 measurements. Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings. The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name. The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory. Measurements saved to balance memory cannot be deleted. You can preview and print out the data saved to the ALIBI database.
Technical Specifications
  • Maximum capacity [Max]: 1 kg
  • Readability [d]: 0.01 g
  • Tare range: -1 kg
  • Repeatability: 0.03 g
  • Linearity: ±0.03 g
  • Stabilization time: 3 s
  • Adjustment: External
  • Display: 5.7” resistive colour touchscreen
  • Protection class: IP 43
  • Communication interface: 2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi
  • Power supply: 100 ÷ 240 V AC 50 / 60 Hz
  • Operating temperature: +15 ÷ +30 °C
  • Storage temperature: -25 - +70 °C
  • Relative humidity: 10% ÷ 85% RH no condensation
  • Weighing pan dimensions: 195×195 mm
  • Packaging dimensions: 490×300×150 mm
  • Net weight: 2.7 kg
  • Gross weight: 3.6 kg
Warranty Information:
  • 2-Year Warranty

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Laboratory > Laboratory Balances > Radwag Laboratory Balances