Home > Tissue Simulation & Phantom >

Pro-Project Pro-CT MK II
Pro-Project Pro-CT MK II


 
Additional Views:


List Price: $7,581.60
Our Price: $6,318.00
You save $1,263.60!




PRODUCT CODE:: 04-410

Accessories

Optional External Beam Hardening Ring 380mm Outside Diameter (04-417) [Add $1,261.00]

Optional External Beam Hardening Ring 350mm Outside Diameter (04-418) [Add $1,261.00]

Optional External Beam Hardening Ring 300 - 380mm Outside Oval Diameter (04-419) [Add $1,105.00]

Optional External Beam Hardening Ring 450 - 550 mm Outside Oval Diameter (04-420) [Add $1,586.00]

 
Details
 
The Pro-CT mk II phantom can be used for carrying out acceptance and constancy tests of computed tomography systems according to IEC 61223-3-5 and the AAPM (American Association of Physicists in Medicine) guidelines. This phantom consists of several test modules placed inside a cylindrical container that can be mounted either directly on a holder of the CT table or on an adjustable stand. It allows accurate alignment for measurements on and off the table. Markings on the phantom and leveling aids provide further facilitation of the positioning process.

The Phantom can be used to do the following tests:
  • Geometric Distortion
  • CT Number (HU) Measurement
  • Noise / Uniformity
  • Artefacts
  • MTF
  • SSP, LSF, PSF
  • CNR
  • Spatial Resolution
  • Spatial Resolution in Z Dimension
  • Contrast Resolution
  • Low Contrast Resolution
  • Slice Profile
  • Alignment
  • Linearity
  • Beamwidth

Features and Benefits

  • Complies with:
    • IEC 61223-3-5
    • IEC 61223-2-6
    • AAPM Guidelines
    • ACR Guidelines
    • 21CFR 1020.33 Specifications
  • CE certified
  • The manual provides detailed guidelines for carrying out each test, results assessment and registration.
  • Main module contains PMMA section with an array of holes 2 mm in diameter, 10 mm deep, placed at 10 mm intervals
  • Low Contrast Module
    • Made of PMMA
    • Contains three groups of low-contrast objects: in each group, there are rods of the same density, 20 mm in height and with a diameter ranging from 1 to 15 mm. Contrast difference between groups and surrounding material is 0.3, 0.6 and 1%
    • Optional subslice targets having a nominal 1.0% contrast and z-axis lengths of 3, 5, and 7 mm. For each of these lengths, there are objects of 3, 5, 7 and 9 mm in diameter (04-411)
  • Sensitometric / Contrast Module
    • Contains 9 sensitometric samples shaped like rods (ø25 mm): PTFE, LDPE, POM-C, ABS, PA-6, PET, air, plastic water equivalent and PMMA – modules body
  • Geometry Module
    • Contains two pairs of aluminium wire ramps whose slope angle tangent is equal to 0.5
    • Middles of ramps intersect on the same plane allowing very precise evaluation of the slice location
    • Contains four ø5 mm rods and four ø3 mm rods from the air in the vertices of the regular octagon close to the outer perimeter of the phantom for evaluating symmetry and circular geometry
    • Optional nine spheres to evaluate the scanner’s imaging of subslice spherical volumes, diameters: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0 and 9.0 mm (04-413)
  • Spatial / High Contrast Module
    • Contains 13 concentrically placed high contrast elements for spatial resolution evaluation from 1 to 13 LP/cm
    • Two tungsten carbide beads ø0.18 mm and ø0.28 mm for MTF and SSP calculation
    • Linear Spread Function (LSF) PTFE / PMMA interface
    • Point Spread Function (PSF) - 0.25 mm stainless steel wire in air
    • Optional, additional concentrically placed high contrast elements for spatial resolution evaluation from 14 to 30 LP/cm (04-414)
  • Water Fillable Module
    • Can be filled with water
  • Pro-water module
    • Mimics true water within 1% accuracy
  • Optional electron density module (04-416)
    • Module made of PMMA
    • Contains samples of 10 different rod-shaped materials (25 mm diameter) with the known physical and electron density corresponding to the following tissues: lungs (inhale), lungs (exhale), breasts (50/50), dense bone, bone marrow, liver, muscles, adipose tissue; additionally, a sample with water and a optional titanium rod
  • Carrying case
Technical Specifications
  • Outside Diameter: 220 mm
  • Length: 250 mm
  • Low Contrast Module
    • Diameter: 200 mm
    • Thickness: 30 mm
  • Sensitometric / Contrast Module
    • Diameter: 200 mm
    • Thickness: 30 mm
  • Geometry Module
    • Diameter: 200 mm
    • Thickness: 30 mm
  • Spatial / High Contrast Module
    • Diameter: 200 mm
    • Thickness: 30 mm
  • Water Fillable Module
    • Diameter: 200 mm
    • Thickness: 35 mm
  • Pro-water module
    • Diameter: 200 mm
    • Thickness: 35 mm
  • Optional electron density module (04-416)
    • Diameter: 200 mm
    • Thickness: 30 mm
  • Optional External Beam Hardening Rings:
    • 380 mm outside diameter (04-417)
    • 350 mm outside diameter (04-418)
    • 300-380 mm outside oval diameter (04-419)
    • 450-550 mm outside oval diameter (04-420)
Warranty Information
  • 1-Year Warranty

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Tissue Simulation & Phantom


$3,014.21
$98.98
$965.35
$1,392.00