The Orbit is a full-function portable spirometer which connects directly to your Personal Computer, laptop or tablet. This spirometer simplifies testing by eliminating calibration and sterilization with disposable nose-clips and pre-calibrated mouthpieces.
This product is compatible with eClinical Works
Features and Benefits
- Standards - The Orbit provides effective diagnostic tests and meets the following Standards:
- American Thoracic Society (ATS/ERS) 2005 Standard
- British Thoracic Society (BTS) Standard
- National Institute for Health & Clinical Excellence (NICE) Guidelines
- Lung Age Calculation - Lung age is calculated for patients ages 20-84. It is equal to the predicted FEV1 that matches the patient’s actual FEV1. Lung age may differ based on the predicted equation chosen.
- Patented, Pre-Calibrated Mouthpiece - With the Orbit spirometer system, everything the patient touches is thrown away. No sterilization or calibration is necessary, saving time for nurses, therapists and physicians.
- No Batteries Required - The Orbit draws its power from the PC it is connected to by USB port.
- Calibration not required
- Compatible with eClinicalworks software
Materials Included
- Orbit Portable Spirometer
- (2) QRS Pre-Calibrated Mouthpieces
- (2) Pressure Tubes
- (5) Nose Clips
- Office Medic Software
- User Manual
Technical Specifications
- Weight: 0.5 lbs.
- Height: 4.3" x 3.7" x 1.7"
- Range (BTPS):
- Flow: ±14 liters/second
- Volume: 0.5-8 liters
- Accuracy (BTPS):
- Flow: ±5% of indication or ±200 ml/sec, whichever is greater for FEF 25-75 and ±10% of indication or ±300 ml/s whichever is greater for PEF
- Volume: ±3% of indication or ±50 ml, whichever is greater for FVC and FEV1; ±10% of indication or ±15 L/min, whichever is greater for MVV
- Precision (BTPS):
- Flow: 5% of indication or 150 ml/sec, whichever is greater for PEF
- Volume: 3% of indication or 50 ml, whichever is greater for FVC and FEV1
- Calibration: ATS 3-speed or standard calibration check
- Predicted Normals:
- Adult: Crapo, Cherniack, Morris, Knudson 1983, Roberts, NHANES III, ECC/ERS/Quanjer
- Pediatric: HSU, Knudson 1983, Polgar, Warwick, NHANES III, Zapletal, Wang, Quanjer
- Measured Parameters: FVC, FEV0.5, FEV1, FEV6, FEV3, FEV1/FEV6, FEV1/FVC, FEV3/FVC, PEFR, PEFT, FEF25%, FEF50%, FEF75%, FEF25-75%, FIVC, FIV0.5, FIV1, FIV3, FIV1/FIVC, FIV3/FIVC, PIFR, FIF50%, FIF25-75%, FIF.2-1.2, FVC/FIVC, Extrapolated Volume, EOTV, FET, MVV, RR, MTV, SVC
- Tests Performed: FVC, Pre/Post Testing, Flow Volume Loop, MVV, SVC
- Measuring Time:
- FVC: 60 seconds
- SVC: 60 seconds
- MVV:15 seconds
- Power Supply:5 Vdc ±5% 100 mA from the host PC USB Port
- Operating Conditions:
- Temperature: 15-40°C
- Humidity: 10-90% (non-condensing)
- Atmospheric Pressure: 700-1060 hPa
- Storage Options
- Temperature: 15-50°C
- Humidity: 90% Max (non-condensing)
- Atmospheric Pressure: 700-1060 hPa
Warranty Information
|
|
|