Modern bedside monitoring platform offering a simple and intuitive touchscreen user interface, plus exceptional visibility. The slender and streamlined monitor design provides convenience and ease in crowded patient rooms. Available in a portable 12" touchscreen display and a larger 19" touchscreen display for stationary use.
Features and Benefits - Configurable display layouts, supporting up to 8 waveforms of data plus a 12-lead display format, enable users to customize their system.
- Utilizes Mortara's unique AM12™ acquisition module with replaceable lead wires, and lead fail indicator for added convenience and efficiency.
- Surveyor S12 includes an integral thermal recorder. Surveyor S19 offers an external, thermal printing solution for added flexibility.
- Communicate with the Surveyor Central using wired technology for a complete patient monitoring solution.
- Allows for easy integration to an existing hospital infrastructure using HL7 and 12-lead ECG output through Surveyor Central.
Technical Specifications
General - Dimensions:
- S12: 12.4 W x 8 H x 4.9" D
- S19: 18.4 W x 11.4 H x 3.8” D
- Weight:
- S12: 6.6 lbs.
- S19: 11.2 lbs.
- Display Type: High-definition, antiglare 16:9 color TFT LCD with LED backlight and resistant touch panel controls
- Display Size:
- S12: 11.6" diagonal; 256mm x 144mm active area
- S19: 18.5" diagonal; 410mm x 230mm active area
- Display Resolution:
- S12: 1366 x 768 pixels
- S19: 1366 x 768 pixels
- Recorder Type:
- S12: Thermal; 2-trace; built-in
- S19: Thermal; 2-trace; external
- Recorder Speed/Resolution: 25mm/s, 200 (v) x 400 (h) dpi
- Print Paper Width: 48mm/50mm
- Print Formats: Strip chart printing of 2 user-selectable waveforms (ECG, IBP, SpO2, CO2)
ECG - ECG Modes: Adult/pediatric
- Simultaneous Leads Available:
- 3-lead patient cable: I, II, III
- AM12: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
- Interpretation: Available with AM12 acquisition module only
- ECG Gain: 2.5, 5, 10, or 20 mm/mV
- Beat Recognition: Normal, ventricular, paced
- HR Measurement Range: 15 –300 bpm
- Pacer Display/Analysis: User selectable
- Arrhythmia Detection: VFib, Asystole, VTach, PVC Run, VRhythm, Couplet, Bigeminy, Sustained Tachycardia, Sustained Bradycardia, Irregular, PVC/m too high, Pause, Pacer Non-Capture
- St Segment Analysis: Sensing leads: any ECG lead available based on lead set used
Respiration - Method 1: Capnography, Range: 0 to 150 bpm
- Method 2: Impedance Pneumography, Via 3 - or 5-lead patient cable, Sensing lead 2, Range: 2 to 120 bpm
Non-Invasive Blood Pressure - Measurement Method: Oscillometric
- Input Connector: Single Lumen Hose (Quick-disconnect fitting)
- NIBP Measurement Range:
- Systolic: 30 - 250 mmHg
- Mean: 20 - 230 mmHg
- Diastolic: 10 - 210 mmHg
- Measurement Modes: Manual or interval (auto) measurement
- Interval Measurement Settings: OFF, 3, 5, 10, 15, 30, 60 minutes
- Pulse Rate Measurement Range: 30 – 240 bpm
Invasive Pressure - Measurement Range: -50 to 300 mmHg
- Pulse Rate Measurement Range: 30 – 250 bpm
Pulse Oximetry - Measurement Method: Absorption – Spectrophotometric (dual wavelength)
- Technology: Nellcor™ OxiMax™ or Mortara Surveyor
- Measurement Range: SpO2: 30 – 100%, calibrated range 70-100%
- Pulse Rate Measurement Range:
- PR with Surveyor SpO2: 30 – 240 bpm
- PR with Nellcor SpO2: 25 – 250 bpm
Temperature - Input Connector: 2-pin connector
- Temp Measurement Range:
- T1 & T2: 5.0 to 50.0°C (41.0 to 122.0°F)
- ΔT: 0.0 to 50.0°C (32.0 to 122.0°F)
- Probe Compatibility: YSI 400-series probes
CO2 - Measurement Method: Side-stream (Non-dispersive IR absorption)
- Technology: Covidien Microstream
- Input Connector: FilterLine®
- Measurement Range:
- etCO2: + FiCO2: 0 to 150 mmHg
- Resp: 0 to 150 bpm
Trends - Trend Data: Up to 72 hours of parameter data
- Trend Display Intervals: 1 min, 5 min, 15 min, 1 hr, 4 hrs
Power - Power Source: AC power/battery
- AC Power Source: External AC power adapter 100 – 240 VAC; 1.2 A max; 50 – 60 Hz
- Battery Type: Internal lithium-ion rechargeable; 8700 mAh
- Battery Runtime:
- Battery Recharge Time:
- Powered Off: 5 hrs maximum
- Powered On:
- S12: 7 hrs maximum
- S19: 20 hrs maximum
|
|
 |
 |
 |
 |

|