This product has been discontinued. For a comparable product, click here for the VI-1220P Venni 12.1” Multi-parameter Patient Monitor.
Designed with emergency and operating room medical responders in mind, the VI-1210P patient monitor provides the efficient and fast-acting response needed for medical emergencies. Minimum ECG waveform and HR distortions during electrosurgical cutting and ablation, and total protection from electrosurgical interference prevent technical interference.
Features and Benefits
- Ultra short recovery time after defibrillation.
- 12.1 inch superior resolution color TFT LCD with maximum 8-waveform display.
- Supports multi-language operating interface which include: English, Spanish, Portuguese, French.
- User-friendly operating interface with feature-rich popup menus, dialogue boxes and rotary mouse.
- Modern ergonomic design. Fully digital monitoring with highly integrated technology.
- Accurate SpO2 measurement in low perfusion situation.
- Fast, accurate blood pressure readings reduce common problems of motion in NIBP measurement.
- Capable of storing up to 360 hours of data records.
- Drug concentration calculation, ST-segment detection, pace-maker analysis and arrhythmia analysis.
- Able to simultaneously display OxyCRG diagram and multi-lead ECG waveforms.
- Audio and visual comprehensive alarm with configurable settings.
- Suitable for monitoring adults, pediatrics and neonates with accessories specifically designed for a variety of patient sizes.
- Energy efficient design with stand-by mode. Choose power from either the extended life build-in rechargeable battery or wall power for ultimate flexibility.
- Built-in WAN technology provides the ability to network with central monitoring system for remote monitoring and diagnosis.
- Optional printing function for data, waveforms, trend tables and trend graphs.
- Optional CO2 detection function.
Standard Components
- ECG
- HR
- Respiration (Dual mode w/ T-RESP)
- SpO2 (Pulse reading & PLETH waveform)
- NIBP
- 2-Ch Temperature (T1,T2)
- Basic Arrhythmia
- Built-In Rechargeable Battery
Technical Specifications
ECG
- ECG Input: 3- or 5-lead ECG cable
- ECG Lead: I, II, III, aVR, aVL, aVF, V
- Gain Choice: X1/4,X1/2,X1,X2,X4 and Auto
- Scanning Speed (mm/sec): 6.25, 12.5, 25, 50
- Heart Rate Range: 15-380BPM
- ECG Calibration: 1mV
- Frequency Response: 0.05-100Hz
- Heart Rate Accuracy: ±1%
NIBP
- Measurement Method: Automatic Oscillometric
- Patient Types: Adults/Pediatrics/Neonate
- Measurement Parameters: Systolic, Mean, Diastolic
- Measurement Range: 10-300mmHg
- Units of Measurement: mmHg/Kpa
- Accuracy: ±2mmHg
Pulse Rate/SpO2
- Display: Waveforms and Digits
- Measurement Range: 0-100%
- Resolution: 1%
- Pulse Rate Range: 30-250BPM
- Accuracy: ±2%
- Resolution: 1BPM
Temperature
- Measurement range: 25.0–45.0°C
- Display: T1, T2, ΔT
- Accuracy: ±0.1°C
Respiration
- Thoracic Impedance or Nasal Tube (Selectable)
- Measurement Range: 0-120BPM Accuracy: ±1BPM
- Resolution: 1BPM
CO2 (Optional)
- Measurement Type: Main Stream
- Measurement Range: 0%-10.0%
- Accuracy: ±2mmHg
Standard Configuration
- ECG, HR, NIBP, SpO2, RESP, TEMP, Drug-concentration calculation, ST-segment detection, pace-maker analysis and arrhythmia analysis, built-in rechargeable battery.
Optional Configuration
- ETCO2, build-in printer, 2-IBP (Dual invasive blood pressure), wall mount, monitor trolley.
|
|
 |