Home > Vital Sign Monitors > Schiller Monitors >

Schiller Tranquility VS Vital Signs Monitor w/ CO2, SpO2, NIBP & Temperature
Schiller Tranquility VS Vital Signs Monitor w/ CO2, SpO2, NIBP & Temperature
Thermometer does not interface with the Schiller Tranquility VS monitor, readings are separate.


 
List Price: $4,814.74
Our Price: $4,012.28
You save $802.46!




Product Code: 2.987648

Details
 
The Schiller Tranquility Vital Signs Patient Monitor offers Patient Monitoring with a simple interface, in a lightweight, portable, battery-powered package.

Features and Benefits
  • Weighing in at less than 3 Lbs.
  • Well suited for any patient care area by offering a multitude of vital sign combinations.
  • Well suited for both bed side and mobile spot check use.
  • Simplifies clinician use by incorporating a touch screen with a simple user interface making the Tranquility VS intuitive for any user.
  • Great for neonatal, pediatric and adult patients.
  • Included SpO2, NIBP, CO2 and Covidien Filac 3000 EZ Thermometer (Thermometer does not interface with the Schiller Tranquility VS monitor, readings are separate)
Materials Included
  • Tranquility VS Monitor
  • 1 SpO2 Sensor Cable
  • 1 SpO2 Adult Reusable Finger Sensor
  • 1 Adult Blood Pressure Cuff
  • 1 Nasal Tube
  • 1 Elbow Adapter
  • 1 Nasal Cannula
  • 1 Sample Line
  • 1 Covidien Filac 2000 Thermometer
  • 1 Probe Cover
  • 1 Lithium Ion Battery
  • 1 Power Cord
  • User Manual
Technical Specifications
  • Physical Dimensions & Weight
    • Base Unit
      • Height: 8"
      • Width: 4.5"
      • Depth: 4"
    • Weight: 2.5 lbs
  • Performance Specifications
    • Display: 5" (Diagonal) Color TFT
    • Resolution: 800 x 3 (RGB) x 480
    • Indicator:
      • Alarm Indicator
      • Power Indicator
      • Pulse beep and alarm sound
    • Trend time: From 1 to 72 hours
  • NIBP
    • Measuring Technology: Automatic oscillating measurement
    • Cuff Inflating: < 30s (0 ~ 300 mmH, standard adult cuff)
    • Measuring Period: AVE < 40s
    • Mode: Manual, Auto, STAT
    • Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
    • Pulse Rate Range: 30 bpm ~ 250 bpm
    • Measuring Range:
      • Adult/Pediatric Mode
        • SYS: 40 ~ 250 (mmHg)
        • DIA: 15 ~ 200 (mmHg)
      • Neonatal Mode
        • SYS: 40 ~ 135 (mmHg)
        • DIA: 15 ~ 100 (mmHg)
    • Resolution: 1mmHg
    • Pressure Accuracy: Maximum Mean error: ± 5mmHg
    • Maximum Standard Deviation: 8mmHg
    • Overpressure Protection:
      • Adult Mode: 280 (mmHg)
      • Neonatal Mode: 150 (mmHg)
    • Alarm Limit:
      • SYS: 50 ~ 240 mmHg
      • DIA: 15 ~ 180 mmHg
    • Standards: Meets performance standards of ANSI/AAMI SP10:2002
  • SpO2:
    • ASpO2: Anti-motion SpO2
    • SpO2 % Range: 0~100%
    • SpO2 Accuracy:
      • ±2% (70 ~ 100%,non-motion)
      • ±3% (70 ~ 100%, motion)
    • Pulse Rate Range: 30-250 bpm
    • Pulse Rate Accuracy:
      • ±2 bpm (non-motion)
      • ±3 bpm (motion)
    • Alarm Upper-Lower Limit:
      • Upper Limit: 70 ~ 100%
      • Lower Limit: 70 ~ 100%
    • SpO2 Probe:
      • Red Light LED Wavelength: 660nm ± 5nm
      • Infrared Light LED Wavelength: 940nm ±10nm
    • Standards: Meets performance standards of EN ISO 9919:2005
  • EtCO2
    • Mode of Sampling: Sidestream or Mainstream
    • Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
    • CO2 measurement Range: 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
    • CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated)
    • O2 Resolution:
      • 0.1mmHg (0-69mmHg)
      • 0.25mmHg (70-150mmHg)
    • CO2 Accuracy:
      • 0 ~ 40 mmHg ± 2 mmHg
      • 41 ~ 70 mmHg ± 5% of reading
      • 71 ~ 100 mmHg ± 8% of reading
      • 101 ~ 150 mmHg ± 10% of reading
      • Above 80 breath per minute ± 12% of reading
    • Sampling rate: 100 Hz
    • Respiration Rate: 2 ~ 150 bpm
    • Respiration Rate accuracy: ±1 breath
    • Response Time: < 3 seconds - includes transport time and rise time
    • Inspired CO2 measurement Range: 3 ~ 50 mmHg
    • Standards: Meets performance standards of ISO/ FDIS 21647:2004 (E), ASTM F1456-01, IEC/CDV 60601-2-55
  • Rapid Temperature:
    • Temperature Measurement Range: 30°C to 43°C (86°F to 109°F)
    • Measurement Times (After Insertion into Measurement Site)
      • 3-5 seconds (Non-Fever Temps)
      • 8-10 Seconds (Fever Temps)
      • Oral Standard Mode: 6-10 Seconds
      • Rectal Mode: 10-14 seconds
      • Direct Mode (All Sites): 60-120 seconds
    • Pulse Timer:
      • 60 Second count with a “beep” at 15 seconds
      • 2 “beeps” at 30 seconds
      • 1 “beep” at 45 seconds
      • 2 “beeps” at 60 seconds
    • Patient Accuracy: A Standard Prediction Mode reading and a Direct Mode reading will differ by less than ±0.2°C (±0.4°F) on 98% of tested patients
    • Batteries:
      • Four “AA” Batteries Required
      • Standard IEC package size.
      • Alkaline --1.5 Volt
      • Approx. 6000 temperature readings
    • Standards: Meets performance standards of EN 12470-3:2000, ASTM E1112:2006
  • Networking
    • Wired Networking
      • Industry standard: 802.11 b/g wired network
      • Frequency Range: 2.412 ~ 2.484 GHz
      • Connected bedside number: Up to 16 bedside monitors
    • Wireless Networking
      • Up to 100 m indoors
      • Industry standard 802.11 b/g wireless
      • Supports TCP/IP and UDP/IP Protocols
  • Power
    • Source: External AC power or internal battery
    • AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
    • Battery: Built-in and lithium Ion rechargeable, 12.6V/5Ah
    • Charge Time: 8 Hours
    • Operating Time: 3 Hours
  • Environmental Specifications
    • Temperature:
      • Operating: 5 ~ 40 °C
      • Storage: -10 ~ 45 °C
    • Humidity Range
      • Operating: : ≤80 %
      • Storage: ≤80 %
  • Fuse: 3.15A/250V
  • LCD Specifications
    • Display Type: TFT Color LCD
    • Size (Diagonal): 5"
    • Active Area:
      • Width: 152.4 mm
      • Height: 91.44
    • Color Arrangement: RGB-Stripe
    • Dot Pitch
      • Width: 0.0635
      • Height: 0.1905
    • Display Mode: Normally White, Transmissive
    • Interface: Digital (TTL)
    • Surface Treatment: Anti-Glare
  • Touchscreen Specifications
    • Type: Four Wire Analog Resistive Touch Panel
    • Input Mode: Stylus Pen or Finger
    • Connector: FPC
    • Insulation Resistance: 25MΩ
    • Voltage: 7VDC
    • Chattering: 10 ms
    • Transparency: 80%
    • Surface Hardness: 3H
    • Durability-Surfacing Scratching: Write 100,000
    • Active Force: 80 gf
    • Knock Test: 1,000,000 times
Warranty Information
  • 18-Month Warranty

Accessories for this product...
Schiller Tranquility VS External Printer Schiller Tranquility VS Rolling Stand
Our Price: $585.62

Add
Our Price: $531.50

Add
Schiller Tranquility VS External Printer Schiller Tranquility VS Rolling Stand

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Vital Sign Monitors > Schiller Monitors
Vital Sign Monitors