Schiller MagLife Serenity MRI Patient Monitor
Schiller MagLife Serenity MRI Patient Monitor


 
Additional Views:





Product Code: MAGLIFE-SERENITY
Call 877-646-3300 for pricing

Details
 

The MAGLIFE Serenity guarantees highest ECG quality during magnetic resonance imaging scanning - even under the strongest gradient influence. The MAGLIFE Serenity is specifically developed to monitor all vital parameters during anesthesia of adults, children and neonates in an MRI imaging environment.

Features and Benefits

  • 12.1-inch color display that is adjustable allowing viewing from various angles
  • Highest ECG quality even under strongest gradient influence (MRI)
  • Several gating outputs for optimal MRI triggering
  • Core and skin temperature measurement by use of an optical sensor
  • State-of-the-art gas analysis during anaesthesia Network compatibility (wireless LAN, fibre cable, LAN)
  • Safe penetration of the Faraday cage
  • Accessories suitable for MRI Flexibility in the configuration of options
  • Optional Trolley with accessory storage available
Materials Included
  • MagLife Serenity Unit
  • (1) Adult SpO2 Sensor
  • (1) ECG Premplifier
  • (1) ECG Cable with 3 Wire Clip
  • (30) ECG Eletrodes
  • (3) Blood Pressure Cuffs
    • 1 Adult Blood Pressure Cuff
    • 1 Pediatric Blood Pressure Cuff
    • 1 Neonate Blood Pressure Cuff
  • (1) Mains Cable
  • (1) Power Adapter
  • (1) 90m Batery
  • User Manual
Technical Specifications
  • Dimensions:
    • Width: 17"
    • Height: 18"
    • Depth: 12"
  • Weight: 51 lbs
  • Environmental Conditions
    • For Operation: 10 - 30 °C (only for use in air-conditioned rooms with a regulated temperature of + 20 °C + 5 °C); atmospheric pressure 700 to 1060 hP
    • For storage and transport: -10 - 50 oC; relative humidity at 0...95% (noncondensing); atmospheric pressure 500 to 1060 hPa
  • Mains Power
    • Protection Class: I
    • Related Voltage Range: 115 / 230 VAC, 50/60 Hz
    • Power Consumption Instrument Fuses: approx. 55 VA 315 mA (T) 250 VAC (230 VAC), 500 mA (T) 250 VAC (115 VAC)
  • Battery Power:
    • Battery 1: Sealed lead battery, 12 V, 17 Ah
      • Operating time: 6 hours
      • Battery Charging: Automatic when monitor connected to power line and turned off
      • Recharging Indicator: Indicator
      • Low battery Indication: Screen Message
      • Recharging Time: 10 Hours
    • Battery Power:
      • Battery 2: Sealed lead battery, 12 V, 4 Ah
        • Operating time: 90 min
        • Battery Charging: Automatic when monitor connected to power line
        • Recharging Indicator: Indicator
        • Low battery Indication: Screen Message
        • Recharging Time: 10 hours (monitor on), 5 hours (monitor off)
  • LCD Screen:
    • Screen
      • Screen Type: VGA, TFT Technology
      • Size: 12.1 inches
      • 128 colors
      • 800 x 600 pixels
    • Sweep Speed
      • 25 mm/s and 50 mm/s
    • Deflection Direction: From Left to Right
    • Waveform Freeze: With pushbutton
    • Backlighting: Cold Cathode Fluorescent Lamp
  • Alarms
    • Physiological and technical alarms:
      • Visual and audible signalling
      • Alarms can be paused for 2 minutes or permanently disabled; if permanently disabled, the monitor beeps every 2 minutes
    • Priorities
      • Physiological alarm (if several modules send alarms at the same time)
      • Technical alarm (if the same module sends several alarms)
    • Frequency of the audio alarm signal: 1000 Hz and 2000 Hz
    • Alarm Delay: 4s (8s at power-up)
  • ECG Signal
    • Signal Input
      • type CF (defibrillation-proof)
      • signal acquisition by ECG sensor with optical wave guide
      • leads I, II, III
      • common mode rejection > 80 dB
      • electrode problem detection
      • patient leakage current < 10 µA
    • Recovery time after defibrillation: 3.5 s
    • Band Pass: 0.5 Hz to 40 Hz (-3 dB) w/o. filter; 0.5 Hz to 22 Hz (-3 dB) with filter
    • Heart rate measuring range: 30 to 250 bpm
    • Accuracy of the heart rate readout: 5 bpm, if T-wave < 0.8 x R-wave (measurement according to AAMI EC13)
    • Heart rate readout in the presence of irregular ECG signals:
      • Measurement according to AAMI EC13: test signal trace
        • a: 90 bpm
        • b: 90 bpm
        • c: 119 bpm
        • d: 90 bpm
    • Response time: 2.5 s between 40 and 80 bpm in an ascending or descending phase (measurement according to AAMI EC13)
    • Sweep speed: 25 mm/s and 50 mm/s
    • Calibration: 1-mV pulse (on screen and printout)
    • Sensitivity: 0.25 - 0.5 - 1 - 2 cm/mV
    • QRS indication: by audible and visual signals
  • Pulse
    • Signal Input: Connection for SpO2 sensor with optical wave guide, type CF applied part (defibrillation-proof)
    • Measuring method: Spectrophotometric
    • Sensitivity: Automatic gain adjustment
    • Averaging: Over 8 s or 16 s
    • Measuring range: 30 to 250 bpm
    • Error: 5 bpm
  • SpO2
    • Signal Input: Connection for SpO2 sensor with optical wave guide, type CF applied part (defibrillation-proof)
    • Measuring Method: Spectrophotometric
    • Sensitivity: Automatic Gain Adjustment
    • Averaging: Over 8 or 16 beats
    • Measuring Range: 0-99%
    • Error:
      • + 1 % between 90 and 100 %
      • + 3 % between 81 and 89 %
      • + 5 % between 55 and 80 %
  • CO2
    • Signal Input: connection for sample line, type CF applied part (defibrillation-proof)
    • Measuring method: spectrophotometric
    • Sensitivity: 3 gain factors: 50, 75, 100 mmHg
    • Measuring Range:
      • EtCO2 : 0 to 270 mmHg (0 to 12.6 kPa)
      • MinCO2 : 0 to 270 mmHg (0 to 12.6 kPa) respiration rate: 2 to 100 resps/min
    • Error
      • EtCO2: + 0.5 % abs. max.
      • MinCO2: + 0.5 % abs. max.
      • Respiration Rate: + 1 resp/m
  • NO2
    • Signal Input: connection for sample line, type CF applied part (defibrillation-proof)
    • Measuring Method: Spectrophotometric
    • Measuring Range: 0 to 950 mmHg
    • Error: + 3 % abs. max
  • O2
    • Signal Input: connection for sample line, type CF applied part (defibrillation-proof)
    • Measuring Method: With measuring cell
    • Measuring Range: 0 -100%
    • Error: + 4 % abs. max
    • Resolution: 1%
  • Non-Invasive Blood Pressure
    • Measuring Method: oscillometric
    • Measuring Range:
      • Adults/children: 10 to 290 mmHg
      • Neonates: 5 to 145 mmHg
    • Signal Input: Type CF applied part (defibrillation-proof)
    • Recovery time after defibrillation: 5 s
    • Error: + 3 mmHg
    • Measuring Range:
      • Adults/Children:
        • Systolic Pressure: 30 to 255 mmHg
        • Diastolic Pressure: 15 to 220 mmHg
        • Mean Pressure: 20 to 235 mmHg
      • Neonates:
        • Systolic Pressure: 30 to 135 mmHg
        • Diastolic pressure: 15 to 110 mmHg
        • Mean pressure: 20 to 125 mmHg
  • Invasive Blood Pressure
    • Signal Input: type CF applied part (defibrillation-proof)
    • Measuring Range: 0 to 300 mmHg
    • Zero: Automatic
    • Error: 4 mmHg
    • Resolution: 1 mmHg
    • Adjustment Range: 30 - 60 - 150 - 300 mmHg
    • Band pass (-3 dB): 0 to 10 Hz (w/o. filter)
  • Temperature:
    • Signal input: Connection for fibre optic probe, type CF applied part (defibrillation-proof)
    • Sensor Application: On the skin surface
    • Measuring Method: Optical Interferometry
    • Error: + 0.3 °C
    • Measuring Range: 20 to 45 °C
    • Resolution: 0.1 °C
  • Recorder
    • Type: Writer with High-Resolution Thermal Print Head
    • Paper: Z-fold pad, Width 70 mm, Length 14m
    • Paper Speed: 25 mm/s
    • Resolution:
      • Vertical: 8 dots/mm
      • Horizontal: 32 dots/mm
    • Print Speed: Horizontally: 10 Characters
    • Start: Single recordings initiated by key press; automatic recordings upon alarm
Warranty Information
  • 1-Year Warranty
Documentation
Brochure

Share your knowledge of this product with other customers... Be the first to write a review