Complete PC based office diagnostic system.

The Universal ECG features accurate results, real-time graphical display and narrative interpretation. The Universal ECG saves you money by eliminating thermal paper and calibration and minimizing required maintenance.

The Orbit portable spirometer features improved accuracy, portability and USB 2.0 connectivity. This next generation QRS Spirometer easily connects with your PC and rests on the table top.

Features and Benefits

ECG Features

  • Incomparable Accuracy - The Universal ECG uses the Louvaine analysis program. The Louvaine algorithm had the best total accuracy of the 9 popular algorithms compared by cardiologists to a standardized database of ECG tracings.
  • Multiple Report Options - Office Medic offers multiple options for viewing the Universal ECG reports and they are transferable to PDF, JPEG, or TIFF formats.
    • 3x4 Simultaneous
    • 3x4 Sequential
    • 6x2 ECG
    • 6x1 ECG
    • Averaged Complexes
    • Measurements Report
    • Avg. Zoom Report
    • Zoom Report
  • Lightweight & Portable - The Universal ECG weighs less than 12 ounces and can easily be transported to new patient rooms, clinic locations or any off site location where an ECG needs to be performed. Also, no batteries are required for the Universal ECG because it draws its power from the computer (connected via USB port).
  • Why Perform Diagnostic ECG Tests? - ECG testing has increased the diagnosis of heart disease. ECG's provide physicians a baseline to compare the health of a heart on a recurring basis. They also help diagnose, monitor and treat patients with symptoms of heart health issues.

Spirometry Features

  • Standards - The Orbit provides effective diagnostic tests and meets the following Standards:
    • American Thoracic Society (ATS/ERS) 2005 Standard
    • British Thoracic Society (BTS) Standard
    • National Institute for Health & Clinical Excellence (NICE) Guidelines
  • Lung Age Calculation - Lung age is calculated for patients ages 20-84. It is equal to the predicted FEV1 that matches the patient’s actual FEV1. Lung age may differ based on the predicted equation chosen.
  • Patented, Pre-Calibrated Mouthpiece - With the Orbit spirometer system, everything the patient touches is thrown away. No sterilization or calibration is necessary, saving time for nurses, therapists and physicians.
  • No Batteries Required - The Orbit draws its power from the PC it is connected to by USB port.
  • Calibration not required.

Materials Included

  • Universal 12-Channel ECG
  • (100) QRS Resting ECG Tab Electrodes
  • (10) Sure-Lock Snap & Tab Electrode Adapters,
  • Lead Placement Guide
  • Orbit Portable Spirometer
  • (2) QRS Pre-Calibrated Mouthpieces,
  • (2) Pressure Tubes
  • (5) Nose Clips
  • Office Medic Software
  • User Manual

Technical Specifications


  • Hub Weight: 250-335 grams (depending on cables)
  • Hub Dimensions: 85 mm x 91 mm x 20 mm (3.3” x 3.6” x .8”)
  • Patient Leads Length
    • Limb Leads: 1 meter
    • Chest Leads: 0.6 meter
  • Patient Leads: 12-Lead Cable (10 Patient Leads)
  • Case Material: ABS Plastic
  • Electrode Connection: 4 mm Banana plug with “snap” or “tab” connectors
  • Display & Operating Console: Dependent on PC
  • Gain Sensitivity: 5, 10, 20 mm/mV
  • Speed: 12.5, 25 and 50 mm/s
  • Input Range: ±6 mV
  • Acquisition Sample Rate: 1000 samples/sec. (Compressed to 500 Hz with peak picking and averaging algorithm)
  • Heart Rate Range: 30 – 170 bpm
  • Frequency Response: 0.05 – 175 Hz ±3dB
  • Defibrillation Protection: Patient leads are isolated from system and operator, with 4kV protection
  • Common Mode Rejection: -60dB (minimum)
  • Safety Standards: Complies with AAMI EC11, EN60601-1, EN60601-2, EN60601-2-25
  • Leads Off Indicators: Connection status for each lead is shown on Acquisition screen
  • Power Source: PC, powered from USB interface
  • Supply Voltage: 4-16 V DC
  • Supply Current: < 17 mA DC
  • Permanent Filters:
    • High Pass: 0.05 Hz 1st order; Low Pass: 170 Hz 1st order
    • Baseline Wander: Baseline reset by adaptive zeroing algorithm
  • Notch filter (Mains Noise Rejection)
    • 50 Hz 4th order Butterworth, 49.1 Hz – 50.9 Hz
    • 60 Hz 4th order Butterworth, 59.1 Hz – 60.9 Hz
  • Low Pass (Muscle Artifact Filter): 35 Hz 4th order
  • Interpretation: Rhythm, Morphology
  • Environmental Conditions:
    • Operating Temperature: 0-40°C
    • Storage Conditions: -20-70°C
    • Humidity: 85% Max. (non-condensing)
  • Weight: 0.5 lbs.
  • Height: 4.3" x 3.7" x 1.7"
  • Range (BTPS):
    • Flow: ±14 liters/second
    • Volume: 0.5-8 liters
  • Accuracy (BTPS):
    • Flow: ±5% of indication or ±200 ml/sec, whichever is greater for FEF 25-75 and ±10% of indication or ±300 ml/s whichever is greater for PEF
    • Volume: ±3% of indication or ±50 ml, whichever is greater for FVC and FEV1; ±10% of indication or ±15 L/min, whichever is greater for MVV
  • Precision (BTPS):
    • Flow: 5% of indication or 150 ml/sec, whichever is greater for PEF
    • Volume: 3% of indication or 50 ml, whichever is greater for FVC and FEV1
  • Calibration: ATS 3-speed or standard calibration check
  • Predicted Normals:
    • Adult: Crapo, Cherniack, Morris, Knudson 1983, Roberts, NHANES III, ECC/ERS/Quanjer
    • Pediatric: HSU, Knudson 1983, Polgar, Warwick, NHANES III, Zapletal, Wang, Quanjer
  • Measured Parameters: FVC, FEV0.5, FEV1, FEV6, FEV3, FEV1/FEV6, FEV1/FVC, FEV3/FVC, PEFR, PEFT, FEF25%, FEF50%, FEF75%, FEF25-75%, FIVC, FIV0.5, FIV1, FIV3, FIV1/FIVC, FIV3/FIVC, PIFR, FIF50%, FIF25-75%, FIF.2-1.2, FVC/FIVC, Extrapolated Volume, EOTV, FET, MVV, RR, MTV, SVC
  • Tests Performed: FVC, Pre/Post Testing, Flow Volume Loop, MVV, SVC
  • Measuring Time:
    • FVC: 60 seconds
    • SVC: 60 seconds
    • MVV:15 seconds
  • Power Supply:5 Vdc ±5% 100 mA from the host PC USB Port
  • Operating Conditions:
    • Temperature: 15-40°C
    • Humidity: 10-90% (non-condensing)
    • Atmospheric Pressure: 700-1060 hPa
  • Storage Options
    • Temperature: 15-50°C
    • Humidity: 90% Max (non-condensing)
    • Atmospheric Pressure: 700-1060 hPa

Warranty Information

  • 3-Year Warranty on ECG
  • 3-Year Warranty on Spirometer

Accessories for this product...
Resting Tab ECG Electrodes, 1,000/bx QRS Resting EKG Tab Electrodes (4000/cs) QRS 3L Calibration Syringe QRS Orbit Nose Clips (Qty 50)
Our Price: $70.00

Our Price: $234.00

Our Price: $336.00

Our Price: $38.00

QRS Resting EKG Tab Electrodes (4000/cs) QRS 3L Calibration Syringe QRS Orbit Nose Clips (Qty 50)
QRS Orbit Mouthpieces (100/bx)
Our Price: $225.00

QRS Orbit Mouthpieces (100/bx)

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

EKG Machines > PC Based EKGs
EKG Machines
Spirometers > PC-Based Spirometers
Welch Allyn Authorized Distributor Volusion Secure Site ABOUT TRUST ONLINE Medical Device Depot is a ShopWiki Approved Store DOTmed Certified: Medical Device Depot PayPal Verified
BBB Accredited Business Physio Control Payment Options Compare prices at