This product has been discontinued. For a comparable product, click here for the Infinium CLEO Capnography Monitor.
The RespSense™ II WIDESCREEN™ capnograph offers Nonin Medical’s sidestream EtCO2 technology for a wide range of clinical settings for both intubated and non-intubated patients. Easy-to-use, accurate and cost-effective, RespSense™ II is perfect for patients in and outside of the hospital, including procedural sedation, resuscitation, EMS transport, sleep labs and homecare.
Features and Benefits
- Meets rigorous ISO requirements for EMS transport
- 1.5-hour trending of EtCO2 and respiration rate
- Easy-to-use, large (7"/17 cm), color touchscreen display
- 36-hour internal memory with USB port
- Adjustable alarm volume
- Configurable selections for language, units of measurement and alarms
Materials Included
- RespSense™ II Unit
- (3) Adult CO2 Sampling Nasal Cannula
- (1) Straight Sampling Line
- (1) Straight T Connector
- (1) Power Supply
- (1) User Manual
Technical Specifications
- Dimensions
- Width: 7.9" (200 mm)
- Depth: 2" (50 mm)
- Height: 5.3" (135 mm)
- Weight: 1.9 lbs (865 grams)
- Capnography Specifications
- Respiration Range: 0 to 99 respirations/minute
- Respiration Accuracy
- 3 to 50 respirations/min ± 2
- 51 to 60 respirations/min ± 3
- EtCO2/CO2 Range: 0 to 99 mmHg (0 to 13.2 kPa)
- EtCO2/CO2 Accuracy:
- ±0.2 kPa / ±2 mmHg, +8% of reading
- 525 – 795 mmHg (700 – 1060 hPA)
- Calculated Update Frequency: Once every breath (“NO BREATH” alarm after 30 seconds)
- Sampling Rate: 4 Hz (4 times per second)
- Total System Response Time: <7 seconds (includes delay time and rise time)
- Drift of Measurement: Within CO2 accuracy specifications for 6 hours of continuous monitoring
- Measurement: Automatic barometric pressure compensation and CO2 temperature compensation
Agent Concentration | Correction of Presented CO2 to Real Concentration | 50 – 70% N2O | Presented CO2 x 0.75 = Actual CO2
| 30 – 50% N2O | Presented CO2 x 0.85 = Actual CO2
| 0 – 30% N2O | No correction
|
- System Specifications
- Power Data:
- Power Supply: 100 – 240 VAC 50 – 60 Hz
- Power Consumption:
- 3.6 W with battery operation
- 9 W with power supply
- Input: 12 VDC, 1.5 A
- Internal Battery
- Type: Lithium Ion (Li-Ion) internal battery, non-field replaceable, rechargeable
- Battery Capacity: Approximately 5 hours
- Charging Time: Approximately 9 hours
- Memory: 36 hours (assuming continuous operation)
- Temperature
- Operating: 0 to 40 °C (32 to 104 °F)
- Storage/Transportation: -40 to 70 °C (-40 to 158 °F)
- Time (from storage) for monitor to be ready for its intended use:
- 10 minutes to warm from -40 to 0 °C
- 19 minutes to cool from 70 to 40 °C
- Humidity
- Operating: 15% to 93% noncondensing
- Storage/Transportation: Up to 93% noncondensing
Warranty Information
|
|
 |
 |
 |
 |

Accessories for this product... |
Nonin Salter Nasal CO2 Sample Line, Infant, Single Use, 25/Pack
|
|
Nonin Salter Nasal CO2 Sample Line, Adult, Single Use, 25/Pack
|
|
Nonin LifeSense/RespSense Carrying Case
|
|
Nonin Salter CO2 Sample Line, Single Use, 25/Pack
|
|
|
|
|
|
|
|
|
|
Nonin Salter Dual Oxygen Delivery CO2 Sampling Nasal Cannula, Adult, Single Use, 25/Pack
|
|
Nonin Disposable Moisture Traps with Filter - Pack of 10
|
|
Nonin Calibration Apparatus, Sens-O-Cal
|
|
Permapure Nafion Tubing, 12 Inches - Box of 10
|
|
|
|
|
|
|
|
|
|
Nonin Straight T-Connector with Sampling Line - Pack of 25
|
|
Nonin Gas Regulator Valve, Sens Valve
|
|
Nonin Verification Gas
|
|
Nonin LifeSense II/RespSense II Power Supply
|
|
|
|
|
|
|
|
|
|
Nonin Salter Nasal CO2 Sample Line, Pediatric, Single Use, 25/Pack
|
|
Nonin Adjustable Pole Mounting Clamp - 2" Sens PMC
|
|
Nonin Salter Dual Oxygen Delivery CO2 Sampling Nasal Cannula, Pediatric, Single Use, 25/Pack
|
|
|
|
|
|
|
|
|
|
|

|