This product has been discontinued. For a comparable product, click here for the Infinium CLEO Capnography Monitor.
The RespSense touch-panel display monitor offers Nonin sidestream EtCO2 technology for a wide range of clinical settings and for both intubated and non-intubated patients. Portable, accurate and cost-effective, RespSense is perfect for sleep labs, procedural sedation, emergency transport (EMS), home care, or in clinical settings where fast, easy EtCO2 monitoring is required.
Features and Benefits
- ISO approved for EMS transport.
- Widescreen touch-panel backlit LCD display.
- Display shows numerical EtCO2 and respiratory rate.
- 1.5 hours of EtCO2 and respiration rate waveform trending.
- Backlit LCD display.
- Audible and visual alarms.
-
Data output via RS-232 port.
- Wide range of optional accessories including:
- Full line of sampling lines
- Carrying case
- Adjustable mounting clamp
- TrendSense memory module, download cable and software
- Sens DAC Digital to analog converter cables for pulse and capnography
Materials Included
- 1 RespSense
- 3 Filters
- 3 Adult CO2 Sampling Nasal Cannulas
- 1 CO2 Sample Line
- 1 Straight T-Connector
- 1 AC/DC Battery Charger
- 1 Manual (CD-ROM)
Technical Specifications
- Battery charger: 120 VAC, 60 Hz for USA / Canada
- Power consumption: 3.6 W at battery operation
- 12 W with battery charger
- Input: 12 VDC, 800mA
- Dimensions: 200 (W) x 135 (H) x 50 (D) mm
- Weight: 800 grams (1.8 lbs)
- Display/Screen Size: 3.5" x 5.5"
- Pump flow: 75 ml/min
- Flow accuracy: ±15ml/min
- Battery Type: Lithium Ion internal battery, rechargeable
- Battery capacity: 10 hours approximately
- Charging time: 17 hours from empty to full
- Respiration range: 3 – 80 respirations/min
- Update frequency: Once every breath
- No breath after 25 seconds
- Respiration accuracy: 3 – 80 respirations/min ± 2
- 51 – 80 respirations/min ± 5
- EtCO2/CO2 range: 0 – 9.9 kPa, or 0 – 99 mmHg
- EtCO2/CO2 accuracy: ±0.2 kPa / ±2 mmHg, +6% of reading
- (EtCO2/CO2 reading reaches its steady state accuracy 10 minutes after power up)
- Update frequency: Once every breath
- Trend length: 1.5 hours
Polysomnography Interface Guide
Warranty Information
- 3-year warranty on main unit.
- 1-year warranty on battery charger.
Documentation Brochure
|
|
 |
 |
 |
 |

Accessories for this product... |
Nonin Battery Charger for Lifesense and Respsense
|
|
Nonin Disposable Moisture Trap with 3 Filters
|
|
Permapure Nafion Tubing, 12 Inches - Box of 10
|
|
Nonin TrendSense Memory Module
|
|
|
|
|
|
|
|
|
|
Nonin Adjustable Pole Mounting Clamp - 2" Sens PMC
|
|
Nonin Salter Nasal CO2 Sample Line, Infant, Single Use, 25/Pack
|
|
Nonin LifeSense/RespSense Carrying Case
|
|
Nonin Salter Dual Oxygen Delivery CO2 Sampling Nasal Cannula, Pediatric, Single Use, 25/Pack
|
|
|
|
|
|
|
|
|
|
Nonin Salter CO2 Sample Line, Single Use, 25/Pack
|
|
Nonin Salter Nasal CO2 Sample Line, Pediatric, Single Use, 25/Pack
|
|
Nonin Salter Dual Oxygen Delivery CO2 Sampling Nasal Cannula, Infant, Single Use, 25/Pack
|
|
Nonin Salter Dual Oxygen Delivery CO2 Sampling Nasal Cannula, Adult, Single Use, 25/Pack
|
|
|
|
|
|
|
|
|
|
Nonin Salter Nasal CO2 Sample Line, Adult, Single Use, 25/Pack
|
|
|
|
|
|
|
|
|
|
|

|