Multi-Energy CT QA Phantom
Multi-Energy CT QA Phantom


 
Additional Views:


This product has a 4-week lead time.
List Price: $11,400.00
Our Price: $11,150.00
You save $250.00!

Product Code: 662-CIRS

Details
 

Note: This product cannot be exported to the following countries: Sweden, Spain, Ireland, United Kingdom, France, New Zealand, Germany, Austria, Italy, Japan, Australia, Belgium, Benelux Region, Bulgaria, Czech Republic, Hungary, Luxembourg, Poland, Romania, Slovak Republic, South Korea, Taiwan, The Netherlands, Turkey, Saudi Arabia, Switzerland, China and Iran.

Multi-Energy CT offers a great improvement in advanced recognition, differentiation, quantification of human tissues and different contrast agents based on their linear attenuation at the different X-Ray energies. A Quality Assurance program using appropriate phantoms, is important to ensure accuracy and reproducibility for ME CT scanner performance.

The CIRS Multi-Energy CT QA (MECT) phantom is designed to assure accurate performance and consistency of Multi-Energy CT scans. The phantom facilitates evaluation of scanner performance allowing users to verify the quantitative accuracy of multi-energy scans, check for artifacts in an extended field-of-view and compare the consistency and stability across different scanners.

The Multi-Energy CT QA (MECT) phantom features a series of 13 iodine in water & blood equivalent inserts, six calcium in water equivalent inserts and a matching kit displaying the same CT numbers at 120 kVp on a conventional CT scanner. See matching kit graph on page 2. All inserts contain a core target of Ø 10 mm inside Plastic Water® -LR for minimizing effects of “beam hardening” and can be positioned in 17 different locations within the scan field. In addition, a water vial plug that can be filled with any fluid. Adipose, Muscle and Water equivalent inserts are also provided. Inserts from the CIRS standard Electron density Phantom (model 062M/MA) can be used for extended testing due to their tissue equivalency of +/- 1% within a wide energy range.

The Multi-Energy CT QA (MECT) phantom consists of nested disks made from CIRS Plastic Water® -LR, representing both head and abdomen configurations. Two 10 cm thick sections surround a 5 cm target section for proper scattering conditions.

Features and Benefits

  • Iodine, calcium, blood, & adipose inserts allow for testing tissue discrimination
  • Verify quantitative accuracy & clinical protocols
  • Verify performance reproducibility for a single scanner and across departments
  • High accuracy in Iodine and Calcium inserts by minimizing “beam hardening”
  • Allows for variable insert positioning
  • Various inserts from CIRS 062M/MA can be used for extensive testing
  • Imaging QA Phantom (CIRS 062QA-35) can be nested inside scattering section
Sample Screenshots





Materials Included

  • (1) Body (50 mm thick)
  • (1) Head (50 mm thick)
  • (2) Annulus Head Insert (100 mm thick)
  • (2) Annulus Body Insert (100 mm thick)
  • (7) Iodine in Water Plugs ( Ø 10 mm Core)
  • (6) Iodine in Blood Plugs ( Ø 10 mm Core)
  • (6) Calcium Plugs ( Ø 10 mm Core)
  • (1) Match Kit (Dense PW-LR & 2.2 mg/cc Iodine in PW-LR ( Ø 10 mm Core)
  • (1) Muscle Equivalent Plug
  • (2) Adipose Equivalent Plug
  • (2) Water Equivalent Plug
  • (1) Water-fillable Plug, Ø 1" removable vial inside (Real water data provided)
  • (1) Holder/Support set
  • (1) Soft Carry Case
  • User Guide

Technical Specifications

  • Dimensions: 13" x 11" 10"
  • Diameter of Head: 7.1"
  • Material: Plastic Water - LR
  • Inserts: 25 solid inserts & 1 water fillable insert (each insert is labeled accordingly)
  • 7 Iodine in Water Inserts: Concentrations of 0.2, 0.50, 1.00, 2.00, 5.00, 10.00 & 15.00 mg/cc
  • 6 Iodine in Water Inserts: Concentrations of 0.00, 0.50, 2.00, 5.00, 10.00 & 15.00 mg/cc
  • 6 Calcium Inserts: Concentrations of 10, 20, 40, 60, 120 and 240 mg/cc
  • Match Kit (Set Of 2)
    • Dense PW-LR (+6%)
    • 2.2 mg/cc Iodine in PW-LR
  • 5 Tissue Equivalent Inserts: Muscle, Adipose & Water
  • Weight: 49 lbs

Warranty Information

  • 1-Year Warranty