Home > Radiology > Tissue Simulation & Phantom >

MRI Distortion Phantom for SRS
MRI Distortion Phantom for SRS


 
Additional Views:


This product has a 4-week lead time.
List Price: $6,317.00
Our Price: $6,217.00
You save $100.00!


Product Code: 603A

Select Model

3D Anthropomorphic Skull Phantom (603A)
3D Anthropomorphic Skull Phantom w/ CT DICOM Data Set (603A-035) [Add $1,253.00]
Software Options

Distortion Check software (License For 2 Years or 25 Successfully Analyzed Scans) (603S-25) [Add $1,643.00]

Distortion Check software (License For 2 Years or 50 Successfully Analyzed Scans) (603S-50) [Add $2,824.00]

Distortion Check software (License for 2 years or 100 Successfully Analyzed Scans) (603S-100) [Add $5,009.00]

Distortion Check Software (License for 2 years or 200 Successfully Analyzed Scans) (603S-200) [Add $9,098.00]

Distortion Check Software (License for 2 years or 500 Successfully Analyzed Scans) (603S-500) [Add $22,845.00]

 
Details
 
CIRS Model 603A was designed for assessment of MR image distortion in Stereotactic Radiosurgery Planning. It’s also a useful tool for verifying image fusion and deformable image registration algorithms used in various treatment planning systems. The tissue equivalent, anthropomorphic design provides the closest conditions to a clinical imaging scenario. The phantom can be imaged using X-ray, Computed Tomography and Magnetic Resonance. It images well with all MRI sequences tested to date, including T1 weighted, T2 weighted, 3D Time of Flight, MPRAGE and CISS.
The skull is manufactured from a plastic-based bone substitute, and the interstitial and surrounding soft tissues are made from a proprietary signal generating water-based polymer. The entire phantom is encased in a clear plastic shell to protect gel from desiccation. It’s supplied with specially designed pads that allow fixation with any stereotactic frame or mounting for end-to-end testing. The phantom is also suitable for frameless SRS QA.

The entire inter-cranial portion of the skull volume is filled with an orthogonal 3D grid of 3mm diameter rods spaced 15 mm apart. Five extended axis-rods intersect at the reference origin of the grid. The end of each extended axis is fitted with CT/MR markers allowing for accurate positioning with lasers and co-registration of CT and MR image sets.

The phantom includes right and left air voids, 3 mm in diameter by 17 mm long to simulate each ear canal for evaluation of potential distortions commonly found in clinical settings.

Note: This product cannot be exported to the following countries: United Kingdom, France, New Zealand, Germany, Austria, Italy, Japan, Australia, Belgium, Benelux Region, Bulgaria, Czech Republic, Hungary, Luxembourg, Poland, Romania, Slovak Republic, South Korea, Taiwan, The Netherlands, Turkey, Saudi Arabia, Switzerland, China and Iran.

Features and Benefits
  • Images well on T1, T2 and 3D TOF MRI acquisitions
  • Images well on CT scans
  • Protective pad for use with Stereotactic Frame
  • Images can be imported into stereotactic localization program
  • CT scans can be used to assess MRI accuracy
  • Optional Phantom Kit with CT DICOM Data Set is available
Software Options



Sample Screenshots



Materials Included
  • 1 3D Anthropomorphic Skull Phantom
  • 1 ABS Cradle
  • 1 Complimentary 90 day license for 5 successful analyzed scans using Distortion Check Software
  • 1 Custom Carry Case
  • 1 SRS Frame Support Cups (set of 4)
  • User Guide
Technical Specifications
  • Dimensions: 12.6" x 9.45" x 7.1"
  • Weight: 12 lbs
  • Materials
    • Skull: Plastic-based bone substitute
    • Interstitial/Soft tissues: Water-base polymer
    • Grid: Reinforced nylon
Warranty Information
  • 4-Year Warranty
Documentation
Brochure

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Radiology > Tissue Simulation & Phantom
Radiology > Tissue Simulation & Phantom > Multi-Modality