Manufacturer

Like us on Facebook   Follow us on Twitter






Click here to visit our Youtube page

McAfee Secure sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams
 

  Home > Vital Sign Monitors >

M8000 Patient Monitor
M8000 Patient Monitor


 

Product Code: 8000NST
Discontinued

Details
 
This product has been discontinued. Click here to return to Vital Sign Monitors.

Features and Benefits
  • 10.4" TFT LCD Display, High Resolution
  • Portable design, stylish and convenient
  • Store and review 1000 pieces of alarm events
Technical Specifications

General
  • Safety: IEC60601 (GB9706)
  • Dimension: 318mm (W) x 264mm (H) x 152mm(D)
  • Power Supply : 100~240V; AC: 50~ 60 Hz
  • Alarm Indication: Visual and audible alarm
  • 1000 groups of alarm events review
  • Application: Adult, Pediatric and neonate
ECG
  • Leads: I, II, III, aVR, aVL, aVF, V
  • Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
  • Input impedance: =5MO (d.c.~60Hz)
  • Common Mode Rejection Ratio: =85dB(diagnostic mode) =105dB(monitoring & surgical mode)
  • Bandwith: 0.5-40Hz (monitoring mode)
  • 0.05-120Hz(diagnostic mode)
  • 1-25Hz (surgical mode)
  • Protection: Segregation breakdown voltage 4000VAC, 50/60Hz
  • Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
  • Indication of Detachment of electrodes: Available
  • Playback of Cardiogram: Available
  • Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
  • Heart Rate Range: 10-300BPM
  • Accuracy: 1BPM
  • ECG waveform playback: 10 minutes
NIBP
  • Method: Automatic oscillometric
  • Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
  • Measurement : Systolic pressure/diastolic pressure/mean pressure
  • Range: Adult: 10-270mmHg
  • Pediatric: 10-235mmHg
  • Neonate: 10-135mmHg
  • Unit: mmHg / Kpa selectable
  • Auto Measurement: 1,2,3,4,5,10,15,20,30,45,60,90 minutes, 2,4,8,12 hours
  • 750 groups of NIBP measuring data review
RESP
  • Method: Impedance Measurement
  • Measuring Range: 0-120bpm
  • Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
  • Apnea alarm: Available
BLT Digital SPO2 (Pulse Oximetry)
  • Range: 0-100%
  • Accuracy: 2% (70%~100%);
  • 3% (35%~ 69%)
  • Unspecified (0~34%)
  • Range & Accuracy of Pulse Rate : 20~250BPM 1BPM
TEMP
  • Channel : 2 channels
  • Range : 0~50
  • Unit : Celsius, Fahrenheit
  • Resolution : 0.1
  • Accuracy : 0.1 (25~50)
  • Alarm Range : 0~50
IBP
  • Channel : 2 channels
  • Range : -50~300 mmHg
  • Resolution : 1 mmHg
  • Accuracy : 2 mmHg (2%) without probe
  • 4 mmHg (2%) with probe
  • Unit : mmHg , Kpa
  • Converter sensitivity: 5 uV/V/mmHg
  • Names of pressures: ART/PA/CVP/LAP/RAP/ICP
EtCO2 (side stream)
  • Method: Infrared spectrum
  • Range: 0.0-13.1%
  • Resolution : 1 mmHg (0.1%)
  • Accuracy : <5% EtCO2, 0.3%
  • >5% EtCO2, <10%( of Readings)
EtCO2 (main stream)
  • Method: Infrared spectrum
  • Range: 0.0-10% (0-76mmHg)
  • Resolution : 1 mmHg (0.1%)
  • Accuracy : 5% (4.0 mmHg) or <10%( of Readings)
Environment Conditions
  • Temperature: Operation 0-40
  • Storage / Transportation : -20-50
  • Humidity: Operation: =85% noncondensing
  • Storage / Transportation : =93% noncondensing
  • Atmospheric Pressure: Operation: 860~1060hPa
  • Storage / Transportation : 500~1060hPa
Technical Specifications
  • 3-year warranty

Share your knowledge of this product with other customers... Be the first to write a review