On-Site Training Included!
The diagnostic cardiology suite with spirometry is a PC-based spirometry platform that helps caregivers enhance patient outcomes and staff efficiency by delivering clinical accuracy, superior service, and seamless connectivity.
Diagnostic Cardiology Suite - Demo
Diagnostic Cardiology Suite & AllScripts TouchWorks EHR - Spirometry Workflow
Diagnostic Cardiology Suite & AllScripts Professional EHR - Spirometry Testing
VIDEO
VIDEO
VIDEO
Features and Benefits
Integrated ambient sensors enter temperature, pressure or humidity values before an exam, so you don’t have to
Help perform exams correctly, the first time, with an incentive screen.
Instantly verify the quality and variability of each test's performance.
Bidirectional connectivity with leading EMR's
Easily access prior exams to monitor treatment plans and asses patient improvement overtime
Uses disposable, single-use transducers to
help reduce the risk of cross contamination between exams.
Securely control user logins, assign user roles and access audit trails
Save PDFs to any network folder
Available with or without syringe
Materials Included
PC-based Spirometery
(1) Spirometry Software on USB
(1) Pressure Tubing
(4) Disposable Flow Transducers
(1) Calibration Syringe (Optional)
User Manual
CPT Code
94010 - Spirometry, including graphic record, total and timed vital capacity, expiratory flow rate measurement(s), with or without maximal voluntary ventilation; National Average Reimbursement: $36.72
94060 - Bronchodilation responsiveness, spirometry as in 94010, pre- and post-bronchodilator administration; National Average Reimbursement: $57.75
Technical Specifications
Test Types: Supported FVC, SCV, MVV, Pre- and Post-bronchodilation
Sensor Type: Pneumotach
Accuracy & Reproducibility: Compliant with ATS/ERS 2005 Guidelines and ISO 26782 Guidelines
Flow Range: +/- 14 L/sec
Volume Range: 0-14 L
Resistance: Compliant with ATS/ERS 2005 Guideline and ISO 26782 Guidelines (Impedance does not exceed 0.15kPa/(L/s) with flows up to 14 L/s)
Interpretation
1991 ATS Interpretation Standards
Lung Age calculation available
Automatic Interpretation available
User-defined interpretation statements available
Parameters
FVC, FIVC, FIV1, FIV1%, FEV0.5, FEV1, FEV2, FEV3, FEV5, FEV6, FEV0.5, FEV0.5%, FEV1%,
FEV1/FVC, FEV2%, FEV3%, FEV5%, FEV6%, PEF, FEF25, FEF50, FEF75, FEF0.2-1.2, FEF25-
75, FEF75-85, PIF, FIF50, FEF50/FIF50, FEV1/FEV6, FET, MEF25, MEF50, MEF75
SVC, ERV, IRV, VT, IC, BF, MV, Tin, Tex, Tin/Tex
MVV, MV, VT, BF, DFRC
Quality Checks
ATS Acceptability and ATS Reproducibility
Effort-quality messages
Audio and visual incentive for coaching patients
Processor: Performance equivalent to an Intel Xeon® class, quad-core with hyperthreading
Resolution: 1024 x 768 or better
RAM: Minimum 4 GB
Operating System
Microsoft Windows 2012 R2 (64-bit)
Microsoft Windows 2016
System Disk: 100 GB for OS and product installation (RAID recommended for data redundancy)
Data Disks: 550 GB hard drive space available HD controller with 128 MB read/write cache (RAID recommended for data redundancy)