Details
 
Balance of the AS R2 PLUS series is a standard analytical weighing device of the SYNERGY LAB line. The AS R2 PLUS is exceptional due to a range of modern constructional and system solutions that guarantee reliability, precision and accuracy of measurement, and make everyday operation easy.

Features and Benefits
  • Ergonomic Mechanical Design
    • The latest AS R2 PLUS analytical balance features spacious weighing chamber, and the open-door clearance facilitates easy access to the weighing pan. With this it is possible to use laboratory glassware of various sizes. New aluminum base is a guarantee for weighing system stability.
    • Dual-CLICK system allows tool-free assembly and disassembly of the weighing chamber, and a special design of guides for weighing chamber panes (no rims) makes keeping the device clean convenient.
    • Innovative construction solutions increase balance durability and reliability in long-term operation.
  • Levelling System
    • Standard AS R2 PLUS balances are equipped with a levelling device located at the front of the weighing chamber, which facilitates level control.
    • Levelling operation is now simplified and easier due to the reduced quantity of adjustable supporting points (2 points).
  • Internal Adjustment
    • Modernized internal adjustment system guarantees accurate indications in extremely unfavorable conditions.
  • Intuitive Operation
    • Balances are equipped with LCD display ensuring clear presentation of the weighing result. Direct access to functions and databases is possible via the following keys:
      • Database – direct access to databases,
      • Function – direct access to basic functions,
      • F1-F4 – programmable function keys and menu navigation keys.
    • AS R2 PLUS analytical balances signal operated working mode, computer connection, battery status, weighing and service functions via pictograms. The quantity of displayed weighing units is also expanded. Dedicated status bar enables display of additional messages, e.g. product name, tare value. Real-time mass measurement is presented using bar graph.
  • ALIBI Memory
    • Data safety is ensured by the ALIBI memory integrated into AS R2 PLUS balances, which enables record of up to 100 000 weighing's. ALIBI guarantees continuity of data collection over a long period of time.
  • Data Protection
    • Access to valuable information is possible after logging. The administrator manages the data access configuration.
  • Databases
    • The information system is based on 5 databases, which allows several users to work with several product databases, and the registered weighing results can be subject to further analysis.
    • The data is registered in 5 databases:
      • Operators (up to 10 users),
      • Products (up to 1000 products),
      • Weighing's (up to 5000 weighing's),
      • Tares (up to 100 tares),
      • ALIBI memory (up to 100 000 weighing's).
  • Communication Interfaces
    • The functionality of AS R2 PLUS balances can be expanded using the following communication interfaces: USB-A, USB-B, RS 232, Ethernet, Wi-Fi®
    • The additional USB port located at the front of the balance enables easy and fast communication with the USB flash drive, it is possible to connect additional devices via this port too.

Functions
  • Autotest: Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Auto test is operated in an automatic mode thus operator’s time is saved.
  • Checkweighing: Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signaled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
  • Dosing: Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bar graph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
  • Parts Counting: Function using mass measurement for determination of measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supported by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platforms of different MAX capacities and different accuracies.
  • Percent Setup: Percent setup function is used for comparison of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly excessed.
  • GLP Procedures: Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
  • Statistics: Statistiscs function registers and analyses performed measurements. This supplies the user with the following information: Max and Min standard deviation, average value, variance, range et.
  • Totalizing: Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
  • Animal Weighing: Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
  • Density Determination: Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of under-pan weighing. Tested load of significant size may be measured this way.
  • Peak Hold: Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.

Technical Specifications
  • Maximum capacity [Max]: 220 g
  • Minimum load: 10 mg
  • Readability [d]: 0.1 mg
  • Tare range: -220 g
  • Standard repeatability [5% Max]: 0.07 mg
  • Standard repeatability [Max]: 0.08 mg
  • Standard minimum weight (USP): 140 mg
  • Standard minimum weight (U=1%, k=2): 14 mg
  • Permissible repeatability [5% Max]: 0.09 mg
  • Permissible repeatability [Max]: 0.1 mg
  • Linearity: ±0.2 mg
  • Stabilization time: 2s
  • Adjustment: Internal (Automatic)
  • OIML Class: I
  • Display: LCD (Backlit)
  • Communication Interface: 2×RS232, 2×USB-A (interchangeable), USB-B, Wi-Fi®
  • Power Supply: 100 ÷ 240 V AC 50 / 60 Hz
  • Operating Temperature: +10 ÷ +40 °C
  • Weighing pan Dimensions: ø100 mm
Warranty Information
  • 2-Year Warranty