ADC, a world leader in core diagnostic products for more than 30 years, has partnered with SunTech Medical®, the premier developer of innovative blood pressure technology, to create the next generation in modular diagnostics: The ADC ADView 2 Modular Diagnostic Station.
Features and Benefits
Clinical-grade Advantage™ BP technology from SunTech Medical
Contemporary, compact design with an integrated handle and easy-to-read display
Manual blood pressure mode for real-time verification
Next-generation EMR ready with HL7 messaging for electronic data transfer
Network enabled with built-in Ethernet or optional Wi-Fi
Lithium-ion power for longer-lasting battery life and a lighter weight
Built-in memory with up to 99 charting sessions
New Pediatric Mode to ensure accurate measurements for younger patients
Firmware upgradeable
This Adview 2 model comes with blood pressure, heart rate and ChipOx Nellcor-compatible SpO2 feature.
Materials Included
Adview 2 Monitor Unit
(1) Lithium Ion Battery
(1) Adult Reusable Cuff
(1) Large Adult Reusable Cuff
(1) Mini USB to USB Cable
(1) Adult SpO2 Finger Sensor
(1) 8' Extension Cable
(1) User Manual
Technical Specifications Dimensions
Height: 8"
Width: 6.75"
Depth: 5.2"
SpO2
Saturation Normal (No Motion): 70-100%Arms ± 2%
Saturation Motion: N/A
Low Perfusion: N/A
Pulse Heart Rate: 20-300 BPM: ±3 BPM
Pulse Heart Rate w/ Motion: 20-300 BPM: ±3 BPM
Blood Pressure/Heart Rate
Range
Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
Heart Rate: 30-220 BPM (Beats Per Minute)
Accuracy: Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
Conditions For Use
Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing - 700 kPa - 1060 kPa.
Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part.
Storage
-20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing - 500 kPa - 1060 kPa.
Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power:
Internal Power Supply
Input: 100-240 VAC @ 1.5A max, 50-60 Hz.
Output: +9VDC @ 5A IEC 320 type input connector.
Calibration
The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems
Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg).
Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Standards
ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications
Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of Liquid
Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.
Videos Adview 2 Demo
VIDEO
Measuring BP, Heart Rate, Temperature & Pulse Oximetry Demo
VIDEO
Taking Automatic & Manual BP Measurements Demo
VIDEO
Using Average Mode Demo
VIDEO
Warranty Information
3-Year Warranty on the Unit
2-Year Warranty on the Blood Pressure Cuffs
1-Year Warranty on the Battery
Documentation Brochure Quick Start Guide