Pro-Project Pro-Dent CT mk II Phantom
Pro-Project Pro-Dent CT mk II Phantom


 
Additional Views:


Note: This item has a 3-10 week lead time.
List Price: $8,876.40
Our Price: $7,397.00
You save $1,479.40!




Product Code: 01-501

Accessories

Additional Homogenous Disc (01-502) [Add $253.50]

 
Details
 

The new Pro-Dent CT mk II phantom is a versatile quality control tool of dental Cone-Beam CT, Dental Volume Tomography (DVT) and other 3D imaging devices according to the Radiation Protection Report no 172 by SEDENTEXCT.

The phantom consists of a main PMMA cylinder that houses modules with different test objects. Thanks to this design, you can perform tests with devices with a small FOV at different positions in the 160mm phantom.

Features and Benefits

  • Noise / Uniformity Section: Uniform PMMA part of the phantom
  • Geometric Distortion Section: An array of 2.0 mm diameter, 3.0 mm long holes uniformly pitched at 10.0 mm intervals
  • Slice Geometry Section: 20mm thick module with two pairs of aluminum ramps and empty rods in vertexes of a square for detailed evaluation of slice thickness and geometry and laser position verification.
  • 5 layer modules section with modules containing
    • Linear Spread Function (LSF) PTFE / PMMA interface
    • Point Spread Function (PSF) - 0.25 mm tungsten steel wire in air
    • XY high contrast resolution (aluminum/polymer) - 1.0, 1.7, 2.0, 2.5, 2.8, 4.0, 5.0 LP/mm
    • Z high contrast resolution (aluminum/polymer) - 1.0, 1.7, 2.0, 2.5, 2.8, 4.0, 5.0 LP/mm
    • 6 low-contrast groups of 1.0, 2.0, 3.0, 4.0, 5.0, 6.0 mm rods made of: aluminum, PTFE, POM-C (delrin), PE-300, air and water emulating epoxy; background made of PMMA
    • 10 mm rods made of aluminum, PTFE, POM-C (delrin), PE-300, air and water emulating epoxy suspended in PMMA - pixel intensity / HU values samples
    • Stacked 20mm diameter contrast-to-noise discs made of aluminum, PTFE, POM-C (delrin), PE-300 and air suspended in PMMA
    • Three 5.0 mm diameter titanium rods embedded in PMMA - beam hardening artefacts
  • Positioning aids on the outside surface of the phantom
  • Test stand with spirit level for accurate placing of the phantom in the test position
  • Folding base for test stand positioning on the X-ray unit’s chair
  • Convenient, portable case for storing and transporting the phantom
  • Optional additional homogeneity disc available