The Capnostream™ 20p patient monitor is built on a legacy of proven performance. For nearly two decades, clinicians have relied on Microstream™ technology for an accurate, continuous view of ventilation adequacy on intubated and non-intubated patients, from neonate to adult. The new Capnostream™ 20p monitor, with the Apnea-Sat Alert feature, alerts caregivers to repetitive patterns of apneas and oxygen desaturation, revealing a more complete picture of a patient’s respiratory status.
Features and Benefits
- Supports current standards of care by providing etCO2 and SpO2 measurements
- Includes Smart Alarm Management™ Integrated Algorithms, a suite of algorithms proven to reduce alarms and simplify the use of patient monitoring to enhance patient safety and improve clinical efficiency
- Screens out low amplitude ‘non-breath’ etCO2 excursions like, talking, crying or snoring.
- Reduces clinically insignificant alarms.
- Alerts clinicians to clinically significant changes in pulse oximetry
- IPI algorithm presents one value that demonstrates real-time respiratory status based on etCO2, RR, PR and SpO2
- Tracks and reports apneas per hour and oxygen desaturation index, and provides the data in trend reports.
- Compatible with central monitoring systems and interfaces with nurse call systems and electronic medical records
- Integrated printer provides convenient bedside documentation
Materials Included
- Capnostream Monitor 20
- (1) Battery Pack
- User Manual
Note: The sensors, airway adapter and nasal filter line are sold separately.
Technical Specifications
- Dimensions:
- Height: 6.6"
- Width: 8.7"
- Depth: 7.6"
- Weight: 7.94 lbs
- Power Supply: Input Voltage 100-240 V, 50/60 Hz, ± 10%
- Microstream Capnography
- Units: mmHg, kPa or Vol%
- Measurement range EtCO2, FiCO2: 0-150 mmHg
- Respiratory Rate: 0 bpm-150 bpm
- Resolution: 1 mmHg
- Accuracy (±SD) etCO2, FiCO2: 0-38 mmHg ± 2 mmHg; 39-150 mmHg ± (5% of reading + 0.08% for every 1 mmHg above 38 mmHg)
- Respiratory rate: 0-70 bpm ±1 bpm, 71-120 bpm ±2 bpm, 121-150 bpm ±3 bpm
- Flow rate: 50 ml/minute (flow measured by volume)
- Waveform Sampling: 50 millisecond intervals
- Response Time: 2.95 seconds
- Initialization Time: 40 seconds
- Calibration Interval: Initial calibration after 1,200 operating hours, then annually or after 4,000 operating hours, whichever comes first
- Pulse Oximetry
- Measurement Range: 0-100%
- Accuracy
- Adult Mode
- SpO2 range 70%-100% ± 2 digits
- SpO2 range 0-69% unspecified
- Neonatal Mode
- SpO2 range 70%-100% ± 3 digits
- SpO2 range 0-69% unspecified
- Pulse Rate
- Range: 20-250 BPM
- Accuracy: ± 3 BPM
- Sat Sec Range: 10, 25, 50, 100