MiniSim 1000 - ECG Arrhythmia Simulator
MiniSim 1000 - ECG Arrhythmia Simulator


 
List Price: $1,296.00
Our Price: $1,080.00
You save $216.00!




Product Code: 300-0.1

Details
 

MiniSim 1000 Arrhythmia Simulator is a powerful yet basic patient simulator in a compact case. It is designed for testing the performance of all ECG monitoring instrumentation quickly and easily. 300his comprehensive microprocessor based instrument is menu driven using the tactile feel keypad and easy-to-follow LCD display.

Full 12 lead ECG simulation with 14 user selectable rates from 30 to 350 BPM, and 14 user selectable amplitudes from 0.15 to 5 mV are all provided by the MiniSim 1000. Sine, Square, and Triangle performance waveforms are simulated with 14 user selectable rates from 0.1 to 100 Hz.

The instrument is also designed to simulate 45 different arrhythmias including atrial, ventricular, tall T wave, ST elevation, ST depression, myocardial infraction, blocks, pulse and pacer waveforms.

Features and Benefits
  • Best Value
  • Easy to Use
  • Compact Size
  • Menu Driven operation
  • Large LCD Display
  • Tactile Keypad
  • Operated on 9V Battery
Materials Included
  • MiniSim 1000 - ECG Arrhythmia Simulator
  • (10) Snap to Banana Adapter
  • (1) Hard Case
  • (1) 9V Battery
  • User Manual
Technical Specifications
  • Dimensions: 5½" x 3½" x 1½"
  • ECG Specifications
    • ECG: 12 leads with independent outputs referenced to RL NORMAL SINUS RHYTHM (NSR)
    • ECG Rates: 30, 60, 70, 80, 90, 100, 120, 150, 180, 210, 240, 270, 300, and 350 BPM. Accuracy 0.5%.
    • Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II. Lead 1 is 0.6 X Lead II, Lead III is 0.4 X Lead II, and Lead V is the same as Lead II.
    • High Level: 500 X low level output on Lead II.
    • Accuracy: 2% (1-5mV)
  • Performance Waveforms (Perf) Specifications
    • Sine, Square, Triangle, Pulse
    • Frequencies: 0.1 to 0.9 in 0.1 Hz steps.1.0 to 9.0 in 1.0 Hz steps.10 to 100 in 10 Hz steps.
    • Amplitudes: 0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II.
    • Pulse: 20 ms pulse of 1mV amplitude repeated at 4 second intervals.
  • R Wave Detection (RWD)
    • Widths: 10, 40, 50, 60, 70, 80, 90, 100, 110, and 120 ms.
    • Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mV on Lead II PACER (PCR)
    • AP: Atrial Pacer set at 70 BPM
    • ASP: Asynchronous Pacer- Ineffective Pacing
    • QRS Amplitudes: 1 mV
    • PCR: Pacer pulses alone
    • Pacer Widths: 0.1, 0.2, 0.5, 1.0, 1.5, and 2.0 ms
    • Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV
    • VP: Ventricular Pacer set at 70 BPM
    • AVP: Atrial Ventricular Pacer set at 70 BPM QRS
    • Amplitude: 1 mV.Pacer Amplitude: -2mV