Home > Biomedical > Electrical Safety Analyzers >

Welch Allyn 9600 Plus Calibration Tester
Welch Allyn 9600 Plus Calibration Tester


 
Additional Views:


List Price: $1,290.20
Our Price: $1,075.17
You save $215.03!




Product Code: 01802-110

Details
 
The 9600 Plus Calibration Tester verifies calibrated temperature accuracy of Braun and SureTemp handheld thermometers and integrated technology monitors from Welch Allyn.

Features and Benefits
  • The tester provides a tightly regulated temperature source that eliminates the setup, precision calibration, and maintenance requirements of water baths and other general purpose calibration equipment.
  • The user takes the “temperature” of the 9600 Plus Calibration Tester with the knowledge and assurance that precise readings are obtained because the unit is factory calibrated to National Institute of Standards and Technology (NIST) or equivalent devices.
  • Verifies calibration accuracy of the Braun and SureTemp thermometers.
  • Displays temperature in degrees Fahrenheit or Celsius
  • Test accuracy at three Calibration Set Point temperatures
  • Simple set-up and operation

Materials Included
  • 9600 Plus Calibration Tester
  • (1) Power Supply
  • (4) Mains Plugs Inserts
  • (1) Hard Carrying Case
Technical Specifications
  • Power Requirements: Voltage: 100 - 240 V 50/60 Hz
  • Current
    • Heating: 480 mA
    • After Warm-Up: 185 mA
  • Power Consumption
    • Heating: 2.4 W
    • After Warm-Up: 0.92 W
  • Dimensions
    • Calibration Tester
      • Length: 254 mm (10”)
      • Width: 105 mm (4.13”)
      • Height: 85 mm (3.34”)
      • Weight (without Power Pack): 0.75 kg (1.65 lbs)
    • Calibration Tester
      • Length: 86 mm (3.38”)
      • Width: 51 mm (2.00”)
      • Height (with plug inserted): 62 mm (2.44”)
      • Weight: 0.18 kg (0.40 lbs)
    • Environment
      • Storage Temperature: 0°C – 50°C (32°F – 122°F)
      • Ambient Operating Temperature: 18.3° C to 26.7°C (65° F to 80° F)
      • Operating Humidity: 20% to 95% RH. Non-Condensing
    • Operating Specifications
      • Controlled Temperature of 9600 Plus
        • Low Setting: 36° C (96.8° F)
        • Intermediate Setting: 38.5° C (101.3° F)
        • High Setting: 41° C (105.8° F)
        • Temperature Accuracy: ±0.05° C (0.1° F)
        • Maximum Pressure/Altitude: < 2000 meter
    • Heating and Cooling Times (Tested at an ambient of 23.9°C (75°F)
      • Room Temperature to Low Setting: Approximately 20 min.
      • Low Setting to Intermediate Setting: Approximately 6 min.
      • Intermediate Setting to High Setting: Approximately 6 min.
      • Cool from High Setting to Low Setting: Approximately 25 min.
Warranty Information
  • 1-Year Warranty

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Biomedical > Electrical Safety Analyzers
Parts > Welch Allyn Parts