The SPECTRO2™l 20 Pulse Oximeter is an easy-to-use spot-check device
that displays %SpO2, pulse rate, signal strength, and Pulse amplitude
Index (PI). Utilizing patented BCI® Serial Autocorrelation technology,
this device responds to challenging environments - including those with
the presence of low perfusion or motion. The SPECTRO2™l 20 Pulse
Oximeter aids health care providers in responding to a wide range of
patient needs, including higher acuity care and ambulatory situations. Features and Benefits- Patented Serial Autocorrelation technology
- Large, bright, easy-to-read LED
- Unique on-board cradle to store and protect finger sensor
- Multiple power options
- Compatible with Docking Station, Attachable Printer, and BCI®
spot-check sensor
- Pulse amplitude Index (PI)
- Low battery indicator
- Nellcor® sensor compatibility
- Reliable performance during motion such as intra- and inter-hospital
transport
- Reliable performance under conditions of low perfusion
- Comfortable ergonomic design allows easy one-handed operation
- Optional printer eliminates possible documentation errors
- Stores patient data for transfer to PC for improved efficiency and
documentation
Materials Included
- Adult spot-check sensor.
- Service Manual (CD)
- "AA" Disposable Batteries (4)
- Sensor Cradles (set of 3 sizes)
Warranty Information
Technical
Specifications
DISPLAYS AND INDICATORS • Keys – ON/OFF
button SpO2 (FUNCTIONAL) • Range 0 to 100% (1% increments); display
maximum 99% • Standard Accuracy Adult / Ped ±2 Arms at 70 - 100% Neonate1
±3 Arms at 70 - 100% Less than 70% unspecified • Low Perfusion
Accuracy Adult / Ped ±2 Arms at 70 - 100% Neonate1 ±3 Arms at 70 -
100% Less than 70% unspecified • Motion Accuracy2 Adult / Ped
±3 Arms at 70 - 100% Less than 70% unspecified • Averaging – 8
beats PULSE SIGNAL STRENGTH • Range 0 to 9 indicator, indicates
logarithmic strength of patient pulse • Display – 9-segment red
LED bargraph 1With the BCI® 1302 Sensor. 2With the BCI® 1300
Sensor. PULSE RATE • Range – 20 - 300 bpm (1 bpm increments) •
Standard Accuracy – ±2 Arms • Low Perfusion Accuracy ±3 Arms over
25 - 250 bpm range Less than 70% unspecified (Pulse amplitude
<1%. Tested using industry standard simulator.) • Averaging – 8
seconds PULSE AMPLITUDE INDEX • Range – 0.03% - 20% (0.01%
increments) • Display – 9-segment green/yellow LED bargraph POWER
REQUIREMENTS • Battery 4 "AA" alkaline or custom 2-cell Lithium
Ion rechargeable battery pack • External (from AC Charger) 9V,
3A output; input of 100-240 VAC, 50Hz, 60Hz • External (from USB) Input:
5V, 500mA max (USB powered source) Output: 9V, 230mA max to oximeter BATTERY
LIFE • Alkaline Cells Life – Approx. 26 hours of use •
Rechargeable Battery Life Approx. 31 hours of continuous use (new) Approx.
3 hours typical recharge time TREND STORAGE • Parameters %SpO2,
Pulse Rate, Pulse amplitude Index and Relative Time • Interval – 4
seconds • Capacity – 144 hours at 4 second intervals MEMORY –
Stores data for up to 99 patients ENVIRONMENT • Operating
Temperature Oximeter and accessories: 0°C to 55°C (32°F to 130°F) Power
supply: 0°C to 40°C (32°F to 104°F) Li+ battery charging: 5°C to
45°C (41°F to 113°F) • Relative Humidity Operating: 15 to 95%
(non-condensing) Storage: 10 to 95% (non-condensing) • Altitude –
Up to 10,000 ft. • Shock and Vibration – Transport per ISO 9919 PHYSICAL •
Dimensions – 3.3W x 6.1H x 1.7D in • Weight – 340g including four
"AA" batteries STANDARDS EN60601-1, EN60601-1-2, ISO 9919
|